TEST RUNNING

Perform test operation and check items 1 and 2 below.
For the test operation method, refer to the operating manual.
The outdoor unit, may not operate, depending on the room temperature.
In this case, press the test run button on the remote control unit while the
air conditioner is running, (use a melallic object to short the two metal
contacts under the battery compartment lid and send the "TEST RUN" sig-
nal from the remote control unit.)
To end test operation, press the remote control unit START/STOP button.
(When the air conditioner is run by pressing the test run button, the OP-
ERATION indicator lamp and TIMER indicator lamp will simultaneously flash
slowly.)
POWER
WARNING
(1) The rated voltage of this product is 115 V AC 60
Hz.
(2) Before turning on the power, check if the voltage
is within the 115 V ±10 %.
(3) Always use a special branch circuit and install a
special receptacle to supply power to the room
air conditioner.
(4) Use a circuit breaker and receptacle matched to
the capacity of the air conditioner.
(5) Do not extend the power cord.
(6) Perform wiring work in accordance with stand-
ards so that the air conditioner can be operated
safely and positively.
(7) Install a leakage circuit breaker in accordance with
the related laws and regulations and electric com-
pany standards.

REMOTE CONTROL UNIT INSTALLATION

CAUTION
(1) Check that the indoor unit correctly receives the
signal from the remote control unit, then install
the remote control unit holder.
(2) Select the remote control unit holder selection
site by paying careful attention to the following:
Avoid places in direct sunlight.
Select a place that will not be affected by the heat
from a stove, etc.
1. REMOTE CONTROL UNIT HOLDER INSTALLATION
Install the remote control unit with a distance of 23 ft(7
m) between the remote control unit and the photocell
as the criteria. However, when installing the remote con-
trol unit, check that it operates positively.
Install the remote control unit holder to a wall, pillar,
etc. with the tapping screw (Fig.19).
1. INDOOR UNIT
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do the air flow-direction louver operate normally?
(4) Is the drain normal?
2. OUTDOOR UNIT
(1) Is there any abnormal noise and vibration during operation?
(2) Will noise, wind, or drain water from the unit disturb the
neighbors?
(3) Is there any gas leakage?
Fig. 18
Short the two metal
contacts under the battery
comoartmert lid.
CAUTION
(1) The power source capacity must be the sum of
the air conditioner current and the current of other
electrical appliances. When the current contracted
capacity is insufficient, change the contracted ca-
pacity.
(2) When the voltage is low and the air conditioner is
difficult to start, contact the power company the
voltage raised.

CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operat-
ing manual:
(1) Starting and stopping method, operation switching, temperature
adjustment, timer, air flow switching, and other remote control unit
operations.
(2) Air filter removal and cleaning, and how to use the air louvers.
(3) Give the operating and installation manuals to the customer.
Fig. 19
Remote control unit
Remote control
holder fixing
unit mounting
1 Set
Remote control
unit holder
2 Push
Tapping
screw
Remote
(small)
control unit
The method of adjusting inter-unit wire harness
To connect inter-unit wire harness to the terminal correctly, please
refer to fig. 20 to adjust the length of the part of Inter-unit Wire har-
ness ahead from conduit holder.
Fig. 20
14AWG
(1:1)
EARTH WIRE
CONDUIT PLATE
CONDUIT CONNECTOR