ELECTRICAL WIRING (INDOOR UNIT)
HOW TO THE INSTALL THE INTER-UNIT WIRE HARNESS
1. Remove the screws, then remove the conduit holder.
2. Fasten the inter-unit wire harness to the conduit holder using the lock nut.
IMPORTANT: Refer to fig. 20 about the length of inter-unit wire harness.
3. Use the screws to install the conduit holder with which Inter-unit wire har-
ness is included.
4. Remove the screws, then remove the wire clamper.
5. Connect inter-unit wire harness to the terminal.
Refer to the wiring diagram.
6. Use the screws to install the wire clamper.
ELECTRICAL WIRING (INDOOR UNIT)
1. Remove the screws, then remove the cord clamp.
2. Connect connection cord to the terminal.
Refer to the wiring diagram
3. Use the screws to install the cord clamp.
Fig. 13
Cord clamp
(There is a
terminal block
inside.)
Screw
Connection cord
HOW TO CONNECT WIRING TO THE TERMINALS
A. For solid core wiring (or F-cable)
(1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip
the insulation to about 15/16" (25 mm) to expose the solid wire.
(2) Using a screwdriver, remove the terminal screw(s) on the terminal
board.
(3) Using pliers, bend the solid wire to form a loop suitable for the termi-
nal screw.
(4) Shape the loop wire properly, place it on the terminal board and
tighten securely with the terminal screw using a screwdriver.
B. For strand wiring
(1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip
the insulation to about 3/8" (10 mm) to expose the strand wiring.
(2) Using a screwdriver, remove the terminal screw(s) on the terminal
board.
(3) Using a round terminal fastener or pliers, securely clamp a round
terminal to each stripped wire end.
(4) Position the round terminal wire, and replace and tighten the termi-
nal screw using a screwdriver.
(1) Match the terminal block numbers and connection
cord colors with those of the outdoor unit.
Erroneous wiring may cause burning of the elec-
tric parts.
(2) Connect the connection cords firmly to the terminal
block. Imperfect installation may cause a fire.
Fig. 12
WASHER
CONDUIT PLATE
SCREW
Cord clamp
Screw
Connection cord
Fig. 14
A. Solid wire
B. Strand wire
Loop
Insulation
Screw with
special washer
Round
terminal
Terminal
Wire
board
Wire
Terminal block
CAUTION
(3) Always fasten the outside covering of the connection
cord with the cord clamp. (If the insulator is chafed,
electric leakage may occur.)
(4) Securely earth the power cord plug.
(5) Do not use the earth screw for an external connector.
Only use for interconnection between two units.
FINISHING
(1) Insulate between pipes.
For rear, right, and bottom piping, overlap the connection pipe
heat insulation and indoor unit pipe heat insulation and bind
them with vinyl tape so that there is no gap.
For left and left rear piping, butt the connection pipe heat insula-
tion and indoor unit pipe heat insulation together and bind them
with and vinyl tape so that there is no gap.
For left and left rear piping, wrap the area which accommodates
the rear piping housing section with cloth tape.
For left and left rear piping, bind the connection cord to the top
of the pipe with vinyl tape.
For left and left rear piping, bundle the piping and drain hose
together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.
CONDUIT CONNECTOR
(2) Temporarily fasten the connection cord along the connection pipe
with vinyl tape. (Wrap to about 1/3 the width of the tape from the
bottom of the pipe so that water does not enter.)
(3) Fasten the connection pipe to the outside wall with a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with
sealer so that rain water and wind cannot blow in.
(5) Fasten the drain hose to the outside wall, etc.
Fig. 16
(Saddle)
Pipe
FRONT PANEL REMOVAL AND INSTALLATION
THE INTAKE GRILLE REMOVAL
(1) Open the intake grille.
(2) Pull down the knob.
Round
(3) Lift the intake grille upward, until the axle at the top of the intake
terminal
grille is removed.
THE INTAKE GRILLE INSTALLATION
(1) The fixing axle of the intake grille is installed on the Panel.
(2) Lay down the intake grille.
THE FRONT PANEL REMOVAL
(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove four screws.
Screw with
(3) The thumb is hung on the lower part as shown in the figure, and it
special washer
pulls to the front, pushing [-] mark , and bottom hooks (two posi-
tion) is removed from wall hook bracket.
(4) The front panel bottom is pulled to the front, and bottom hooks is
Round
terminal
removed indoor unit.
(5) The front panel is pulled to the front, raising the upper surface,
and a front panel is removed.
THE FRONT PANEL INSTALLATION
(1) Firstly, fit the lower part of the front panel, and insert top and bot-
tom hooks. (Three top sides, six bottom sides)
(2) Four screws is attached.
(3) The intake grille is attached.
Indoor unit
Bottom hole
(six position)
Fig. 15
Connection pipe
(heat insulation)
Bind the pipes together
to that there is no gap.
Pipe
Drain hose
For connection from the left rear
Wall pipe
(Outside wall cap)
(Sealer putty)
Check the following:
(Outdoors)
Drain hose
GOOD
Wall
Saddle
Fig. 4
Intake grille
Push
[-] mark
Push
Top holes (two sides)
Top hole (center)
Bottom hooks
(six position)
Indoor unit
Front panel
Overlap the insulation
Indoor unit pipe
(heat insulation)
Vinyl tape
Wrap with cloth tape
Cloth tape
Left piping
Connection cord
Pipe
Drain hose
Connection cord
Connection pipe
Drain hose
View from indoors
BAD
BAD
BAD
Lifted up
Wave
End in water
Intake grille
Mounting shaft
Bearing
Front panel
Knob
Screws
(4 position)
Front panel
Front panel
Wall hook bracket
Top hook (center)
Front panel
Top hooks
(two sides)