OPERATION continued
CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
SHOCK HAZARD
DO NOT splash or pour water
onto control panel or wiring.
Always use an inset.
DO NOT place food directly
into the warmer.
Always pour hot water into the
warmer before it is preheated.
DO NOT pour water into a
dry, heated warmer. This may
damage the unit.
DO NOT put ice into a
warmer pan. This will cause
condensation on the inside of
the warmer. Damage caused
by condensation is NOT
covered by warranty.
Stir thick food items frequently
to keep food heated uniformly.
Keep insets covered to
maintain food quality and
temperature.
AUTOFILL WARMERS
1.
Autofill warmers sense water level by a sensor placed at the proper
level. For manifolded autofill warmers, the water level sensor / fill tube
is in one pan only.
2.
Water fills the pan through an inlet tube. All other sections if
manifolded, fill at the same time through the drain manifold.
3.
The autofill function is active only when the thermostat for the pan with
the water level sensor is turned ON .
4.
Make sure the drain valve is fully closed before turning any t-stats ON.
5.
DO NOT use autofill warmers in the dry mode. This may damage the
water level sensor probe. NEVER turn the thermostat ON for the pan
with the probe and fill tube unless the entire warmer unit is to be used in
the wet mode.
6.
Clean water level sensor daily to maintain water level in warmer.
OPERATION
1. Always use an inset. DO NOT place food directly into the
warmer.
2. Check water level in wet-operation warmer frequently during
use. Running warmers dry will lower the temperature of the
food in the insert pan, and may damage the warmer.
3. Alternating between wet and dry operation in any individual
warmer is NOT recommended.
4.
DO NOT use metal tools, steel wool, or caustic or abrasive cleanser to
clean warmer pan.
WARMERS WITH MANIFOLDED DRAIN
1.
Water poured into any one section will seek the same water level with
all sections on the manifold.
2.
Make sure the drain valve is fully closed before filling warmer.
3.
All units that are manifolded with the AUTOFILL unit, MUST be on
the same elevation and completely level with each other to operate
correctly.
10