CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightening flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
* Service mode, error code list, exploded view, PCB assembly, parts list and circuit diagrams are given in this manual to assist the service technician in maintaining the Model VR800. * The following accessories are supplied with VR800/VR800Z as the standard accessories. Owner's manual, VR800...
D-SUB 25-pin SCSI-2, unbalanced transfer method Asynchronous Recording / reproducing Data backup Internal 3.5” E-IDE hard disk drive (VR800) Internal ATAPI zip drive (VR800Z) External fixed / removable hard disk drive (optional) SCSI-2 or better 44.1 kHz 16-bit linear Not available A.D.A.C.
Page 5
6 (7 including [LOCATE] key temporary memory) + 99 LCD Bargraph 10 dots (- , -30, -24, -18, -12, -9, -6, -3, 0, OVER) -12dB 254 (W) x 285 (D) x 100 (H) Approx. 2.0 kg 100V AC 120V AC 230V AC 15 W VR800 / VR800Z...
The VR800 software can be updated through the SCSI port. This means that unscrewing and opening up the VR800 panel is not necessary to change the EPROMs. Please refer to the following explanation for correct software updating procedures. 3-1. Method of Sending Software from Fostex Japan There are two ways of sending the VR800 updated software.
Page 10
VR800 / VR800Z 4-2. Flash ROM & CPU version 4-3. DA Test This mode is used to check the Flash ROM and CPU versions : blinking currently installed in the unit. In order to check the version number, press the [EXECUTE/ YES] key while “?”...
Page 11
AUTO RTN START AUTO PUNCH IN AUTO PUNCH OUT AUTO RTN END CLIPBOARD IN CLIPBOARD OUT EXIT / NO / EJECT VR800 / VR800Z Key/Button/Jog Dial EXECUTE / YES RECORD TRACK 1 RECORD TRACK 2 RECORD TRACK 3 RECORD TRACK 4...
Page 12
VR800 / VR800Z 4-5. Self Check <Cable Connection in “ Self Check ” Mode> WORD OUT SCSI OPTICAL External SCSI Device Optical cable Fs, DIGITAL IN, DIGITAL OUT and SLAVE MODE settings on the disk to be used when the Self Check test is executed should be as follow.
Page 13
The following is considered to be the cause of problem. • The internal drive is not installed in the VR800. • Breaking, shortage and / or bad contact of flat cable J12. • Bad soldering of gate array U5 on the MAIN PCB. VR800 / VR800Z...
Page 14
VR800 / VR800Z 4-5-3. MIDI In/Out Check Even if the before mentioned prompt is displayed, pressing the [EXECUTE/YES] key would reach the next test. 4-5-4. S/P DIF In/Out Check Even if the before mentioned prompt is displayed, pressing the [EXECUTE/YES] key would reach the next test.
Page 15
If not, it means that the vari-pitch circuit does not work correctly. As a result, the prompt below will be displayed. The following is considered to be the cause of problem. • Defects on the vari-pitch circuit (U3, U9), gate array (U5) and / or surrounding circuit. VR800 / VR800Z...
Page 16
VR800 / VR800Z 4-6. Offset Display 4-7. Initializing Disk : blinking This mode determines if the offset value against a master machine should be displayed when the VR800 is working as a slave machine. If you would like to turn “ON” the offset display, press the [EXECUTE/YES] key while “?”...
Page 17
SCSI port. However, if something wrong happens when updating the software (e.g. A blackout occurred while updating the software.), the VR800 might not be able to boot up by the system software inside the Flash ROM. VR800 / VR800Z...
Page 18
VR800 / VR800Z 4-9. Free Block Check 4-11. Test 1 : blinking This mode is used to check the condition of the diskette inserted into an external SCSI drive connected to the VR800 or the internal drive. (As mentioned before, the SCSI drive has a priority unless the SCSI ID is set to “6”.)
There is an overlapping section in program management region. There was improper access to program management region. There was improper access to program management region when saving System File. There was improper access when fading in/out. ERROR CODE LIST DESCRIPTION VR800 / VR800Z...
• The internal drive must be set to “MASTER”. • There are 4x inch screws and 8x metric screws are included in the VR800 as well as the VR800Z. When fixing the HDD to the bracket, use the inch screws. On the other hand, use the metric screws when fixing the zip drive to the bracket.
Page 21
4) Connect the J12 (40-pin flat cable) and W1 (4-pin cable) from the MAIN PCB assy to the internal drive connectors In order to connect pins straight, twist the cable as shown below. 4) Tighten 6 x screws (BBT 3 x 8 BZn) fixing the bottom panel of the VR800. VR800 / VR800Z...
Page 29
REOLACE ONLY WITH SAME TYPE FUSE. PRECAUTION : EN VUE DE LA PROTECTION CONTINUELLE CONTRE LES RISQUES D’INCENDIE, REMPLACER AVEC LE MEME TYPE DE FUSIBLE. C925 C924 C928 R927 C909 R926 C929 R915 R115 D106 L105 C110 C109 R114 VR800 / VR800Z BH9595 C927 L102...