Weber Q Series Owner's Manual

Weber Q Series Owner's Manual

Hide thumbs Also See for Q Series:

Advertisement

Thank you for
purchasing a
WEBER grill.
Take a few minutes
and protect it by
registering your
product online at
www.weber.com.
Q 1000 Q 1200
845CO-0015
0845
GRILL OWNER'S GUIDE
If you smell gas:
• Shut off gas to the appliance.
• Extinguish any open flames.
• Open lid.
• If odour continues, keep away from the appliance and
immediately call your gas supplier or your fire department.
Leaking gas may cause a fire or explosion which can cause serious
bodily injury, death, or damage to property.
• Never operate this appliance unattended.
• Do not use grill within 610 mm (2 ft) of any combustible
material. Combustible materials include, but are not limited to
wood or treated wood decks, patios or porches.
• Never operate this appliance within 7.5 m (25 ft) of any
flammable liquid.
• If a fire should occur, keep away from the appliance and
immediately call your fire department. Do not attempt to
extinguish an oil or grease fire with water.
Failure to follow these instructions could result in fire, explosion or
burn hazard, which could cause property damage, personal injury
or death.
m WARNING: Carefully follow all
leak-check procedures in this
Owner's Guide prior to grill
operation. Do this even if the
grill was dealer-assembled.
m WARNING: Do not ignite
this appliance without first
reading the BURNER IGNITION
sections of this Owner's
Guide.
Q 2000 Q 2200
845CO-0016
0845
m DANGER
m DANGER
THIS GAS APPLIANCE IS
DESIGNED FOR OUTDOOR USE
ONLY.
This Owner's Guide contains
important information necessary
for the proper assembly and safe
use of the appliance.
Read and follow all warnings and
instructions before assembling
and using the appliance.
EN_ASIA - INTERNATIONAL ENGLISH
71829
05/01/18

Advertisement

Table of Contents
loading

Summary of Contents for Weber Q Series

  • Page 1 If you smell gas: purchasing a • Shut off gas to the appliance. • Extinguish any open flames. WEBER grill. • Open lid. Take a few minutes • If odour continues, keep away from the appliance and immediately call your gas supplier or your fire department.
  • Page 2: Warnings

    See instructions in this Owner’s Guide for correct procedures. m Do not operate the gas grill if there is a gas leak present. m Do not use a flame to check for gas leaks. WWW.WEBER.COM...
  • Page 3: Table Of Contents

    WEBER SPIDER/INSECT SCREEN(S) ......20 The use and/or installation of parts on your WEBER product that are BURNER TUBE PORTS .
  • Page 4: Parts List

    PARTS LIST .................1 ..................1 ........1 ...............1 ......1 ..............1 ......1 ..................1 ................1 ....................1 ................... 2 ..................2 ................2 ....................2 WWW.WEBER.COM...
  • Page 5: Assembly

    ASSEMBLY WWW.WEBER.COM...
  • Page 6: Weber Q 1000 Exploded View

    WEBER Q 1000 EXPLODED VIEW Q 1000_ASIA_LPG_080116 Handle Spacer Handle Cooking Grate Burner Tube Igniter Electrode Assembly Cookbox Carrying Handle Rear Cradle Front Cradle Push Button Igniter Hose Bracket Gas Cartridge Valve a. Hose (May not be included) b. Regulator...
  • Page 7: Weber Q 1200 Exploded View

    WEBER Q 1200 EXPLODED VIEW Q 1200_ASIA_LPG_060117 Thermometer Handle Spacer Handle Cooking Grate Burner Tube Igniter Electrode Assembly Cookbox Carrying Handle Rear Cradle Front Cradle Electronic Igniter Button & Module Hose Bracket Gas Cartridge Valve a. Hose (May not be included) b.
  • Page 8: Weber Q 2000 Exploded View

    WEBER Q 2000 EXPLODED VIEW Q 2000_ASIA_LPG_040218 Handle Spacer Handle Cooking Grate Side Table Burner Tube Igniter Electrode Assembly Cookbox Carrying Handle Rear Cradle Front Cradle Push Button Igniter Hose Bracket Valve a. Hose (May not be included) b. Regulator...
  • Page 9: Weber Q 2200 Exploded View

    WEBER Q 2200 EXPLODED VIEW Q 2200_ASIA_LPG_040218 Thermometer Handle Spacer Handle Cooking Grate Side Table Burner Tube Igniter Electrode Assembly Cookbox Carrying Handle Rear Cradle Front Cradle Electronic Igniter Button & Module Hose Bracket Valve a. Hose (May not be included) b.
  • Page 10: Important Information About Lp Gas & Lp Gas Connections

    LPG Gas B/P - 30 mbar / 2.8 kPa - 28-30 / 37 mbar B/P - 50 mbar Q 1000, Q 1200 0.79 0.79 0.71 Q 2000, Q 2200 0.94 0.94 0.84 CYLINDER CONSUMPTION DATA CYLINDER MAIN BURNER MAXIMUM WWW.WEBER.COM...
  • Page 11: Connecting The Regulator To The Cylinder

    For replacement hose, regulator, and valve assemblies, contact the Customer Service Representative in your area using the contact information on our web site. Log on to www.weber.com. WWW.WEBER.COM...
  • Page 12: Preparing To Use Your Grill

    NOTE: All factory-made connections have been thoroughly checked for gas leaks and the burners have been flame- tested. As a safety precaution, however, you should check all fittings for leaks before using your gas grill. Shipping and handling may loosen or damage a gas fitting. WWW.WEBER.COM...
  • Page 13 OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com. D) When leak checking is complete, turn gas supply off at the source and rinse connections with water.
  • Page 14: Disconnecting The Regulator

    Push in on regulator lever (5) until it releases from cylinder (6). Disconnect by Sliding Collar Make sure regulator lever is in the off position (7) (9). Slide the collar of the regulator up (8) (10) to disconnect from the cylinder. B) Exchange empty cylinder for a full cylinder. WWW.WEBER.COM...
  • Page 15: Safety Checks Before Using Your Grill

    For your convenience, you can also line the removable habit of performing a few catch pan with a WEBER disposable drip pan, which will safety checks before grilling. help keep the removable catch pan cleaner longer.
  • Page 16: Burner Ignition & Usage

    CAUTION: Do not fold in side tables until grill is cold (Q 2000, Q 2200). Some batteries have a plastic protective wrap around them. This plastic must be removed before you attempt to ignite your grill. Do not confuse this plastic with the battery label. WWW.WEBER.COM...
  • Page 17: Lighting With A Match

    TO EXTINGUISH BURNER Push burner control knob in and turn it clockwise to the off ( ) position. m CAUTION: Do not fold in side tables until grill is cold (Q 2000, Q 2200). WWW.WEBER.COM...
  • Page 18: Barbecuing Tips & Helpful Hints

    For more barbecuing tips and recipes, visit move food to another area of the correct cooking temperatures. www.weber.com. cooking grate. Any flames will • Sear meats and cook with the lid quickly subside. After flames down for perfectly grilled food subside, relight the grill.
  • Page 19: Troubleshooting

    THIS IS NOT A DEFECT. Clean thoroughly. Refer to “CLEANING THE INSIDE OF THE GRILL.” If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com. WWW.WEBER.COM...
  • Page 20: Annual Maintenance

    NOTE: If a spider/insect screen becomes damaged or cannot be cleaned, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com. BURNER TUBE PORTS Over time, from repeated use of the grill, the burner tube ports will become dirty.
  • Page 21: Burner Tube Cleaning Or Replacement

    CAUTION: The burner tube opening (7) must be positioned properly over the valve orifice (8). m WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting. C) Reinstall the lid. D) Replace cooking grates. WWW.WEBER.COM...
  • Page 22: Routine Maintenance

    For your convenience, you can also line the removable catch pan with a WEBER disposable drip pan, which will help keep the removable catch pan cleaner longer. Cleaning the removable catch pan is just as important as cleaning the cookbox.
  • Page 23: Ignition System Operations

    Make sure the electronic igniter button is working by listening for clicking and looking for sparks at burner. If the electronic ignition system still fails to ignite, contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com. WWW.WEBER.COM...
  • Page 24 ATTENTION: This product has been safety-tested and is only certified for use in a specific country. Refer to country designation located on outside of box. These parts may be gas-carrying or gas-burning components. Please contact Weber-Stephen Products LLC Customer Service Department for genuine Weber-Stephen Products LLC replacement part(s) information.

This manual is also suitable for:

Q 1000Q 1200Q 2000Q 2200

Table of Contents