Topping up the system pressure

External filling loop
Once the external filling loop and pressure gauge/menu has been
located, follow the instructions for re-pressurising the system.
▶ Unscrew the blanking cap [1].
▶ Attach the hose [2] to the valve.
– Usually one end of the hose is already connected to one of the
system fill isolation valves.
▶ Ensure both ends [3] of the hose are screwed on hand tight.
▶ Monitor the pressure at the display.
– The system fill isolation valves [4] are in a closed position (the
handle/screwdriver slot is across the valve).
▶ Turn the handle/screwdriver slot through 90° to open valves and
slowly fill the system.
– The system fill isolation valves [5] are opened (the handle/
screwdriver slot is in-line with the valve).
– The pressure at the display will start to rise.
▶ Set the pressure between 1 and 1.5 bar pressure.
▶ Turn the handles/screwdriver slots back, through 90°, to close the
valves.
– The system fill isolation valves [6] are in a closed position (the
handle/screwdriver slot is across the valve).
▶ Top up the system pressure, if as a result of the air bleeding the
pressure drops off.
Once the pressure has settled between 1 and 1.5 bar.
▶ Ensure the valves are closed.
▶ Remove the hose [2] and replace the blanking cap [1].
1
eco
!
bar
%
kWh
6
Fig. 3
If the pressure reads more than 1.5 bar as a result of over filling:
▶ Bleed one radiator until the pressure gauge returns to between 1 and
1.5 bar.
Greenstar 8000 Life – 6720883870 (2019/02)
3
2
eco
eco
!
!
bar
%
bar
kWh
kWh
5
4
0010025545-001
4

Operating the appliance

4.1

Control panel overview

7
6
5
Fig. 4
Control panel
[1]
Display
 and  keys: To navigate through menus and increase/decrease
[2]
settings
[3]
d key: Return/back
[4]
OK key: Save settings, Chimney sweeper key (Service Engineer
function): press 5 seconds for chimney sweeper mode
[5]
eco key: Hot water preheat selection (only available if the optional
integral diverter valve kit is fitted)
[6]
Hot water key: Adjusting the hot water temperature (only available
if the optional integral diverter valve kit is fitted)
[7]
Heating key: Heating mode on, set the maximum flow
temperature
4.2

Symbols in the display

Symbol
Explanation
Central heating ON
%
Is displayed with the appliance status code and diagnostic
code during a fault condition.
Burner ON/OFF
Connection with the Wi-Fi network (only available with
accessories)
Connection with RF transmitter, e.g. Comfort+ II RF room
thermostat (only available with Key accessories)
chimney sweep mode
Service mode
Eco-Mode
Hot water ON (only available if optional integral diverter
valve kit is fitted)
Table 3 Symbols in the display
Operating the appliance
eco
ok
5 sec
4
1
2
reset
3
0010021505-001
7