Topping Up The System Pressure; Operating The Appliance; Control Panel Overview; Symbols In The Display - Worcester Greenstar 8000 Life User Instructions

Gas fired condensing regular boiler
Hide thumbs Also See for Greenstar 8000 Life:
Table of Contents

Advertisement

3.3

Topping up the system pressure

External filling loop
Once the external filling loop and the external pressure gauge have been
located, follow the instructions for re-pressurising the system.
▶ Unscrew the blanking cap [1].
▶ Attach the hose [2] to the valve.
– Usually one end of the hose is already connected to one of the
system fill isolation valves.
▶ Ensure both ends [3] of the hose are screwed on hand tight.
▶ Monitor the pressure via the external pressure gauge.
– The system fill isolation valves [4] are in a closed position (the
handle/screwdriver slot is across the valve).
▶ Turn the handle/screwdriver slot through 90° to open valves and
slowly fill the system.
– The system fill isolation valves [5] are opened (the handle/
screwdriver slot is in-line with the valve).
– The pressure at the display will start to rise.
▶ Set the pressure between 1 and 1.5 bar pressure.
▶ Turn the handles/screwdriver slots back, through 90°, to close the
valves.
– The system fill isolation valves [6] are in a closed position (the
handle/screwdriver slot is across the valve).
▶ Top up the system pressure, if as a result of the air bleeding the
pressure drops off.
Once the pressure has settled between 1 and 1.5 bar.
▶ Ensure the valves are closed.
▶ Remove the hose [2] and replace the blanking cap [1].
1
6
Fig. 2
If the pressure reads more than 1.5 bar as a result of over filling:
▶ Bleed one radiator until the pressure gauge returns to between 1 and
1.5 bar.
Greenstar 8000 Life – 6720883873 (2021/05)
3
2
5
4
0010026889-001
4

Operating the appliance

4.1

Control panel overview

7
eco
6
5
Fig. 3
Control panel
[1]
Display
 and  keys: To navigate through menus and increase/decrease
[2]
settings
[3]
d key: Return/back
[4]
ok key: Save settings, Chimney sweeper key (Service Engineer
function): press 5 seconds for chimney sweeper mode
[5]
eco key: Hot water preheat selection (not applicable for regular
appliances)
[6]
Hot water key: Adjusting the hot water temperature (not
applicable for regular appliances)
[7]
Heating key: Heating mode on, set the maximum flow
temperature
4.2

Symbols in the display

Symbol
Explanation
Central heating ON
Is displayed with the appliance status code and diagnostic
code during a fault condition
Burner ON/OFF
Connection with the Wi-Fi network (only available with
accessories)
Connection with RF transmitter, e.g. Comfort+ II RF room
thermostat (only available with Key accessories)
chimney sweep mode
Service mode
Eco-Mode (not applicable for regular appliances)
Hot water ON (not applicable for regular appliances)
Table 3 Symbols in the display