3.3

Topping up the system pressure

Integral keyless filling link
Locate the filling link and follow the instructions for re-pressurising the
system.
Fig. 3
▶ Re-pressurise the system.
– Pull the lever [1] down to start the filling process.
▶ When the pressure, shown on the display, reaches between the 1 and
1.5 bar,
– Release the lever [1] to stop the filling process.
▶ Top up the system pressure, if as a result of the air bleeding the
pressure drops off.
1
eco
!
%
bar
kWh
Fig. 4
If the display reads more than 1.5 bar as a result of over filling:
▶ Bleed one radiator until the pressure, shown on the display, returns
to between 1 and 1.5 bar.
3.3.1

Greenstar Intelligent Filling System (accessory)

Fig. 5
Greenstar Intelligent Filling System
Greenstar 8000 Life – 6720883872 (2019/02)
0010023634-001
1
eco
!
bar
%
kWh
0010024971-001
0010023397-001
An Intelligent Filling System is available as an accessory.
The Intelligent Filling System refills the water into the heating system as
required. Your specialist programmes the Intelligent Filling System
according to your heating system. Have your specialist explain the
function of the Intelligent Filling System to you.
Automatic refilling keeps the pressure in the heating system at the
programmed value.
4

Operating the appliance

4.1

Control panel overview

7
eco
6
5
Fig. 6
Control panel
[1]
Display
 and  keys: To navigate through menus and increase/decrease
[2]
settings
[3]
d key: Return/back
[4]
OK key: Save settings, Chimney sweeper key (Service Engineer
function): press 5 seconds for chimney sweeper mode
[5]
eco key: Hot water preheat selection
[6]
Hot water key: Adjusting the hot water temperature
[7]
Heating key: Heating mode on, set the maximum flow
temperature
4.2

Symbols in the display

Symbol
Explanation
Central heating ON
Is displayed with the appliance status code and diagnostic
code during a fault condition.
Burner ON/OFF
Connection with the Wi-Fi network (only available with
accessories)
Connection with RF transmitter, e.g. Comfort+ II RF room
thermostat (only available with Key accessories)
chimney sweep mode
Operating the appliance
1
reset
ok
5 sec
3
4
0010021505-001