FortiGate-5140 chassis

FortiGate-5140 shelf managers

FortiGate-5140 Chassis Guide
01-30000-0396-20070201
Table 4: Telco alarm connector pin assignment (Continued)
Pin
Name
10
AMINCOM
11
AMANO
12
AMANC
13
AMACOM
14
APRCO
15
APRCOM
Shield
Shelf-GND
The FortiGate-5140 chassis includes two identical redundant hot-swappable shelf
managers, located in the dedicated shelf manager slots on the right of the
FortiGate-5140 front panel. The primary shelf manager is installed above the
secondary shelf manager. The FortiGate-5140 and 5050 chassis include the
same shelf managers.
The shelf managers support redundant operation with automatic switchover. If
both shelf managers are operating normally, one acts as the active shelf manager
and the other as the standby. Usually the primary shelf manager would be the
active shelf manager and the secondary shelf manager would be the standby
shelf manager. The shelf managers monitor each other and either can trigger a
switchover if necessary. The active shelf manager performs all shelf manager
functions. If the active shelf manager fails or is removed, the standby shelf
manager takes over all shelf manager functions.
The FortiGate-5140 shelf managers control chassis power up and power down,
chassis power distribution, monitor chassis operating parameters, monitor and
control chassis cooling, and can signal alarms if the chassis encounters problems.
All FortiGate-5000 modules installed in the chassis communicate with the shelf
managers.
The FortiGate-5140 shelf managers are factory installed. In most cases users do
not have to install or configure the shelf managers.
Each shelf manager has two ethernet interfaces (ETH 0 and ETH 1). You can
connect to ETH 0 from the shelf manager front panel. ETH 1 connects to the
FortiGate-5140 backplane.
The shelf managers detect alarm conditions and communicate alarm signals to
the FortiGate-5140 shelf alarm panel. The shelf alarm panel also contains serial
interfaces for connecting to the shelf managers.
The shelf managers are hot swappable. You can remove a shelf manager by
opening the extraction lever until the hot swap LED starts blinking. When the hot
swap LED turns solid blue you can remove the shelf manager from the
FortiGate-5140 chassis.
FortiGate-5140 shelf managers
Description
MinorAlarm - COM
MajorAlarm - NO
MajorAlarm - NC
MajorAlarm - COM
PwrAlarm - NO
PwrAlarm - COM
Shelf Ground