Setting Digital Meter Board Pc4 Dip Switches - Miller SuitCase 12RC CE Owner's Manual

Wire feeder with gun and meters
Hide thumbs Also See for SuitCase 12RC CE:
Table of Contents

Advertisement

6-2. Setting Digital Meter Board PC4 DIP Switches

Wire Speed
Settings
Wire Speed In
Inches Per Minute
Wire Speed In
Meters Per Minute
1
2
3
.
Meter DIP switches are factory set
to display voltage using 14-pin
feedback. Meter hold feature is
factory set to off position.
Shows switch in ON/DOWN (closed) position.
Shows switch in OFF/UP (open) position.
Shows switch does not affect this function.
Voltage Display
Settings
Display Volts
Using Sense Lead
Display Volts
Using 14-Pin
1
Front Meter Panel
2
S1 DIP Switch
3
S2 DIP Switch
If the DIP switches are set to a Meter
Hold (ON) position, the meter value
will hold 5 seconds after gun is trig-
gered. The meter value will continue
to hold for 8 seconds after trigger is
released or until gun is re-triggered.
Amperage Display
Settings
Display Amps Using
Current Sensor
Display Amps
Using 14-Pin
Meter Hold
Settings
Meter Hold ON
Meter Hold OFF
Ref. 803 141
OM-263984 Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Suitcase 12rc non-ceSuitcase 12rc

Table of Contents