Section 6 − Operation; Controls - Miller SuitCase 12RC CE Owner's Manual

Wire feeder with gun and meters
Hide thumbs Also See for SuitCase 12RC CE:
Table of Contents

Advertisement

6-1. Controls

Internal Side View
OM-263984 Page 18
SECTION 6 − OPERATION
1
2
3
4
5
Front Panel
7
JOG
Internal Control Panel
1
Power Control Switch
2
Trigger Hold Switch
(If applicable)
Depress the switch to On to weld
without holding gun trigger through-
out the weld cycle.
To start weld, press and release gun
trigger. To end weld, press and re-
lease gun trigger.
Depress the switch to Off to turn trig-
ger hold Off.
3
Meter Display (If applicable)
4
Volts, Wire Feed Speed Or
Amps Select Switch
(If applicable)
.
Meter is factory set to display
voltage and wirefeed speed. To
display voltage and amps refer to
Section 6-2 for DIP switch set-
tings.
5
Voltage Control
6
6
Wire Speed Control
Use control to adjust wire speed.
7
Purge Switch
Press switch to momentarily energize
gas solenoid and purge air from gun,
and to adjust shielding gas regulator.
8
Jog Switch
Use Jog position to momentarily feed
welding wire at speed set on Wire
Speed control without energizing
welding circuit or shielding gas valve.
Close and latch door.
8
Ref. 263 838-A / 804 213-B / 263 250-A