Wiring Diagrams - Scotsman Prodigy C0322 Technical & Service Manual

Prodigy series modular cuber. includes prodigy plus d models
Table of Contents

Advertisement

Wiring Diagrams

17-3055-01
LIQUID
LINE
W
SOLENOID
DUMP
W
VALVE
W
R
BN
WATER
R
BK
LEVEL
SENSOR
BK
ICE
THICKNESS
PROBE
SUMP TEMP.
SENSOR
DISCHARGE
TEMP.
SENSOR
THIS UNIT MUST
BE GROUNDED.
C0522R, C0530R, C0630R, C0830R, C1030R - Single Phase A - B Series
C0630R, C0830R, C1030R - Single Phase D Series
USE COPPER CONDUCTORS ONLY
WATER
MOT
PUMP
SOLENOID
BN/W
W
R/W
BU
W
V
W
J10
1
2
3
J9
GN/Y
Y
1
2
3
4
J1
HIGH PRESSURE
CONTROL
ELECTRONIC
CONTROL
J7
J8
1
2
1
2
CURTAIN SWITCH
SEE NAMEPLATE FOR
PROPER VOLTAGE REQUIREMENTS
AND MAXIMUM FUSE SIZE
BN/W
HARV ASSIST
HOT GAS
W
SOLENOID
SOLENOID
LOAD
O
LINE
TRANSFORMER
W
BK
BK
L1
T1
CONTACTOR
L2
T2
W
RUN
CAP
W/R
W/Y
W/R
Y
PTCR
BK
GN/Y
BU
BU
2
3
CRANKCASE HEATER
PROTECTOR
JUNCTION
INTERNAL
BOX
GROUND
SCREW
EARTH GROUND
1
REMOTE
COMPRESSOR
CONDENSER
POWER SUPPLY
MORE THAN ONE DISCONNECT MEANS MAY BE
FAN
REQUIRED TO DISCONNECT ALL POWER TO THIS UNIT.
January 2015 Page 82
1 DASHED LINES INDICATE FIELD WIRING WHICH MUST BE
INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE AND ALL STATE AND LOCAL CODES.
2 WIRE COLOR FOR 208-230/60/1 AND 115/60/1 UNITS: BLACK
3 WIRE COLOR FOR 115/60/1 UNITS: WHITE
WIRE COLOR FOR 208-230/60/1 UNITS: BLACK W/WHITE STRIPE
L1
LINE
TRANSFORMER
12V
ELECTRONIC CONTROL
GN/Y
WATER
SUMP
LEVEL
TEMP.
SENSOR
DISCHARGE
TEMP.
CONTACTOR T1
EARTH
GROUND
BK
DUMP
BK
VALVE
Y
R
TERMINAL BOX
R
C1
S2
BK
R3
W
COMPRESSOR
N
OR
CRANKCASE HEATER
L2
HARVEST ASSIST
SOLENOID 1
HOT GAS VALVE
WATER VALVE
CONTACTOR
HIGH
COIL
PRESSURE
CONTROL
(WC ONLY)
CURTAIN
ICE
SWITCH 1
THICKNESS
PROBE
CURTAIN
SWITCH 2
(2 PLATE UNITS ONLY)
LIQUID LINE
WATER
SOLENOID
PUMP
PTCR
RUN
CAP.
REMOTE CONDENSER FAN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents