Control Button Use - Continued - Scotsman Prodigy C0322 Technical & Service Manual

Prodigy series modular cuber. includes prodigy plus d models
Table of Contents

Advertisement

Control Button Use - continued

Change De-Scale Notification Interval
Like the others, this feature is accessible only from standby (Status Light Off).
1. Press and hold harvest button for 3 seconds.
Starts the Time to Clean Adjustment State and displays the current time to clean setting.
2. Press the clean button repeatedly to cycle through the 4 possible settings:
Rev 5 and up (10/08 production start)
• 1 year (8760 hours)
• 0 (disabled)
• 4 months (2920 hrs)
• 6 months (4380 hours) (default)
Prior
• 6 months
• 5 months
• 4 months
• 3 months
3. Press Off or leave untouched for 60 seconds to select the displayed interval
Test Mode Sequence Table - Air or Water Cooled
Time (seconds)
0
30
40
50
55
70
75
85
95
Test Mode - Remote
Test Time (seconds)
0
30
40
50
55
70
75
80
85
On
WIV - 30 seconds
WP - 10 seconds
WP, PV, HGV - 10 seconds
HGV, Comp -
Comp - 15 seconds
None -
HGV - 10 seconds
Fan - 10 seconds
None All –
On
WIV - 30 seconds
WP - 10 seconds
WP, PV, HGV - 10 seconds
HGV, Comp - 5 seconds
Comp - 15 seconds
None - 5 seconds
HGV - 5 seconds
BV - 5 seconds
None
January 2015 Page 32
Off
WP, HGV, Comp, Fan, PV
WIV, HGV, Comp, Fan, PV
WIV, Comp, Fan
5 seconds WIV, WP, Fan, PV
WIV, HGV, WP, Fan, PV
5 seconds All
WIV, WP, Comp, Fan, PV
WIV, HGV, WP, Comp, PV
Test Complete
Off
WP, HGV, Comp, BV, PV
WIV, HGV, Comp, BV, PV
WIV, Comp, BV
WIV, WP, BV, PV
WIV, HGV, BV, WP, PV
All
WIV, WP, Comp, BV, PV
WIV, HGV, WP, Comp, PV
All – Test Complete

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents