Cleaning - D Series - Scotsman Prodigy C0322 Technical & Service Manual

Prodigy series modular cuber. includes prodigy plus d models
Table of Contents

Advertisement

Cleaning - Prodigy Plus D Series
All models have an indicator light that switches on to
inform the user that the cleaning interval has been
reached. It does not stop the machine from making
ice.
All models have a Clean mode. In the D series
machines, it is a single step, automatic system.
A single push of the Clean button puts the machine
into a Manual Harvest to release any ice and warm
up the system, then it drains the reservoir and refills
it. The cleaning process is designed to use straight
nickel safe ice machine scale remover, added
between draining and refilling. The controller will
indicate the proper time to add the scale remover by
blinking A d 1.
The rest is automatic, the controller will circulate and
then flush out the scale remover. No manual timing is
needed.
After the scale remover has been drained out, the
water distributor must be inspected for loose scale
and cleaned of any. Removal of the sump cover,
pump bracket and curtain is next to be sure those
parts have been cleaned.