Code
Description
001
Internal Error
System had to
reload default
settings.
002
Power Failure
Power state does
not match feedback
loop state.
050
Shorted
temperature probe.
051
Open temperature
probe.
075
Brew basket lock or
sensor failure.
Basket was in place
when brew cycle
started, but was
pulled out during the
brew cycle. If this
error occurs, the
brew basket lock
has failed, or the
sensor is out of
adjustment.
100
Initial Fill Error
Initial fill time was
more than 8.6
minutes.
101
Error on refill
Tank did not refill
within 2 minutes.
102
Unwanted Fill
When brewer is idle,
the fill valve was
activated for more
than 30 seconds
during a 1 hour
period.

Error Codes

Possible Cause
Corrective Action
Control board
Clear error.
failure.
Re-program the
brewer to the desired
specifications. If error
occurs again, replace
control board.
Relay on control
Replace control
board has failed.
board.
Probe failure.
Replace probe.
Bad probe
Check all
connection, or
connections.
probe failure.
Replace probe if
necessary.
Brew basket lock
Repair or replace
has failed or sensor
brew basket lock, or
needs adjustment.
adjust sensor.
Water supply flow
Watch for short
rate is too low.
potting during brew
cycle. Investigate
cause of low flow
rate. (Clogged water
filter, etc.)
Water supply flow
Watch for short
rate is too low.
potting during brew
cycle. Investigate
cause of low flow
rate. (Clogged water
filter, etc.)
Possible leak in
Check inside of
tank, fitting, or
machine for leaks.
valve.
Output on control
Replace control
board has failed,
board.
causing a dispense
valve to open.
How to Clear Error Codes
Software Ver. 1.51
and lower
Enter
programming
mode, then exit
programming
mode.
Enter
programming
mode, then exit
programming
mode.
Enter
programming
mode, then exit
programming
mode.
Enter
programming
mode, then exit
programming
mode.
Press the
flashing control
panel power
switch to resume
operation.
Press the control
panel power
switch.
Error message is
cleared
automatically at
end of brew
cycle.
Enter
programming
mode, then exit
programming
mode.
12
Software Ver. 2.0
and higher
Turn main power
switch off and
on.
Turn main power
switch off and
on.
Turn main power
switch off and
on.
Turn main power
switch off and
on.
Press the
flashing control
panel power
switch to resume
operation.
Press the control
panel power
switch.
Error message is
cleared
automatically at
end of brew
cycle.
Turn main power
switch off and
on.

Hide quick links: