Code
Description
001
Internal Error
System had to reload
default settings.
050
Shorted temperature probe.
051
Open temperature probe.
075
Brew basket lock or sensor
failure.
Basket was in place when
brew cycle started, but was
pulled out during the brew
cycle. If this error occurs,
the brew basket lock has
failed.
100
Initial Fill Error
Initial fill time was more
than 15 minutes.
101
Error on refill
Tank did not refill within 3
minutes.
102
Unwanted Fill
When brewer is idle, the fill
valve was activated for
more than 30 seconds
during a 1 hour period.
200
Flat Line Temperature
(Water is boiling)
System is calling for heat,
but the temperature does
not rise at least 2°F within
10 minutes.
201
Heater Open
System is calling for heat,
but the temperature does
not rise at least 2°F within
10 minutes. This error is
disabled during brewing
and while using the hot
water faucet.
202
Heater Short
System is not calling for
heat, but temperature rises
more than 5°F.
255
Keypad Error
A switch was pressed for
more than 45 seconds.

Error Codes

Possible Cause
Control board failure.
Probe failure.
Bad probe connection,
or probe failure.
Brew basket sensor or
lock has failed.
Magnet in brew basket
handle is missing or
loose.
Water supply flow rate
is too low.
Water supply flow rate
is too low.
Possible leak in tank,
fitting, or valve.
Output on control
board has failed,
causing a dispense
valve to open.
Triac is stuck closed,
bad output on control
board, or temperature
is set too high for
altitude.
Heating element
failure.
Possible triac stuck
closed, or bad output
on control board.
Switch was held in too
long, or switch is stuck
closed.
13
Corrective Action
Clear error.
Re-program the brewer to
the desired specifications. If
error occurs again, replace
control board.
Replace probe.
Check all connections.
Replace probe if necessary.
Repair or replace brew
basket sensor or lock.
Remove brew basket
handle. Place magnet in
correct position.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter,
etc.)
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter,
etc.)
Check inside of machine for
leaks.
Replace control board.
Check triacs, check control
board output, or adjust
temperature for altitude.
Check and replace heating
elements if necessary.
Check triac and control
board.
Clear error and try again. If
error occurs without switch
being pressed, replace input
board.
How to Clear Error
Codes
Turn main power
switch off and on.
Turn main power
switch off and on.
Turn main power
switch off and on.
Press the flashing
control panel power
switch to resume
operation.
Press the control
panel power switch.
Error message is
cleared
automatically at
end of brew cycle.
Turn main power
switch off and on.
Turn main power
switch off and on.
Turn main power
switch off and on.
Enter programming
mode, then exit
programming
mode.
Turn main power
switch off and on.

Hide quick links: