Adjustments
Run Solenoid
1. When ignition switch is in the RUN position, the run
solenoid should energize and position the fuel stop lever
to within 1/16" (1.6 mm) of stop on the injection pump.
2. If adjustment is needed, loosen lock nut and rotate
the threaded end of the swivel until the lever is properly
positioned.
3. Tighten lock nut. Recheck adjustment.
Kubota Diesel Engine (Rev. A)
1
1. Run solenoid
2. Fuel stop lever (run)
1. Run solenoid
2. Fuel stop lever (off)
Page 3 − 4
4
3
Figure 1
3. Swivel
4. Lock nut
1
Figure 2
3. Injection pump stop
Groundsmaster 4100−D
2
2