Leakages.
Service solutions:
Take of the cover to be able to see the Container on the left hand
side.
Let the dishwasher take in water and check the level.
If the level is too high (leakage through the top of the Container)
-
adjust the pressure level switch
-
check assembling ofthe Container to tub, misaligned oring or
screw not tightened.
-
Check the Container it self (leakages between the welded base
and the Container walls)
Low water level.
Check ifthe Container is clogged. Clean it with hot water (after
disassembly it from the pressure level switch hose and the tub)
under a tap.
If the water level is to low, adjust the pressure level switch.
The drain pump is always running if the water
prot device is activated.
If there is a leaking point and the water prot device is activated the
d-pump is running continuously.
There are no possibilities for the drain system to evacuate water
from the bottom tray, so when the d-pump has emptied the tub it
will still drain but without draining any water out: Customer
complaint, not draining?!
Even in this case the Service tech have to locate the leaking point
Leakages:
If the leakage point is located to the d-pump check:
-
the two screws holding the d-pump on to the tub.
-
the oring between the d-pump / tub (misaligned, distorted) ??
-
the housing three screws on the d-pump.
If the leakage point is located to the d-pump check:
-
the two screws holding the bracket / circulation pump in place.
-
disassemble the circulation pump from the tup and check for
„plastic burr" in the tub / oring connection.
Spares Operation - R.Kurzke 11/06
between 20 - 24 mm
- 38 -
Water level
599 528 133 EN