Circulation Pump

The circulation pump is driven by an asynchronous
motor with an starting winding. The starting winding
ist in circuit with a 2,5 μF (Euro) capacitor. (2 μF UK)
Rating:
Main winding resistance
Starting winding resistance

Drain Pump

The drain pump is driven by a synchronous motor.
Power output
Pump rate
Main winding resistance
Thermostats
(normally open)
45°C
closes at 41°C
opens at 33°C
55°C
closes at 50°C
opens at 42°C
65°C
closes at 61°C
opens at 53°C
Overheating protection (normally closed)
opens at 83°C
closes at 0°C
Electronic EDW 503
On electronic models, a micro processor controls all
components, this is done using triacs. The electronic also
memorizes all programme data.
The heating is switched by a relay on the electronic board.
Spares Operation - R.Kurzke 11/06
60/80 W
158 Ohm
158 Ohm
21/19 W.
10-12 l/min.
200 Ohm
- 6 -
599 528 133 EN