Daikin VRV III-S RXYMQ6PV4A Service Manual page 134

For high outdoor temperature use, r-410a
Table of Contents

Advertisement

SiME34-608
Malfunction
code
Outdoor Unit
LA
LC
P1
P4
System
U0
U1
U2
U3
U4
U5
U5
U7
U8
U9
UA
UC
UE
UF
UH
Central
UE
Remote
Controller
M1
and
Schedule
Timer
M8
MA
MC
Heat
64
Reclaim
65
Ventilation
68
6A
6A
6F
94
The system operates for malfunction codes indicated in black squares, however, be sure to check and repair.
Troubleshooting
Operation
Inspection
Unit No.
lamp
display
9
9
9
9
9
9
8
9
8
7
9
9
9
9
9
9
9
9
9
9
7
8
9
9
9
9
9
9
9
9
8
8
9
9
9
9
9
9
9
9
8 or 7
9
8 or 7
9
8 or 7
9
8 or 7
9
8
7
8
7
8
7
8
7
9
9
8
7
9
9
Malfunction contents
Malfunction of power unit
9
Malfunction of transmission between inverter and
9
control PC board
High voltage of capacitor in main inverter circuit.
9
Malfunction of inverter radiating fin temperature rise
8
sensor
Low pressure drop due to refrigerant shortage or
9
electronic expansion valve failure
Reverse phase / open phase
9
Power supply insufficient or instantaneous failure
9
Check operation is not completed.
9
Malfunction of transmission between indoor and
9
outdoor units
Malfunction of transmission between remote
9
controller and indoor unit
Failure of remote controller PC board or setting
7
during control by remote controller
Malfunction of transmission between outdoor units
9
Malfunction of transmission between main and sub
7
remote controllers (malfunction of sub remote controller)
Malfunction of transmission between indoor unit and
9
outdoor unit in the same system
Improper combination of indoor and outdoor units,
9
indoor units and remote controller
Address duplication of central remote controller
8
Malfunction of transmission between central remote
9
controller and indoor unit
Refrigerant system not set, incompatible wiring /
9
piping
Malfunction of system, refrigerant system address
9
undefined
Malfunction of transmission between central remote
9
controller and indoor unit
Central remote controller PC board defect
9
Schedule timer PC board defect
Malfunction of transmission between optional
9
controllers for centralized control
Improper combination of optional controllers for
9
centralized control
Address duplication, improper setting
9
Indoor unit's air thermistor error
9
Outside air thermistor error
9
Malfunction of HVU
9
Damper system alarm
9
Damper system + thermistor error
9
Malfunction of simple remote controller
9
Internal transmission error
9
Troubleshooting by Remote Controller
8: ON
7: OFF
9: Blink
Page
Referred
168
169
170
171
173
175
176
178
178
179
180
182
183
184
186
187
188
189
190
191
193
123