Care and maintenance
instructions
Coarse filter
The coarse filter traps larger food particles, which cannot get
past the drain pump. Empty the coarse filter as necessary.
1 Lift the coarse filter by the handle.
2 Empty the coarse filter. Remember to replace it!
Fine filter
Debris that collects on the fine filter is automatically rinsed away
during each wash. However, the fine filter and its pipe section
should be cleaned a couple of times a year.
1 Turn the handle counterclockwise once.
1x
2 Lift the pipe section straight up by the handle. Free the coarse
filter to clean the pipe section.
3 Remove and clean the fine filter.
4 Replace in reverse order. Check that the edges seal properly
when replacing the fine filter.
5 Lock the filter in place by turning the handle clockwise to the
stop position. The handle should point straight out from the
dishwasher.
12
Coarse filter
Fine filter
Pipe section
1x
Customer Care Center 1-800-898-1879
www.askona.com

NOTE!

The dishwasher must not be used without the filters in place!
Dishwashing results may be affected if the coarse filter is
incorrectly fitted.
Drain pump
The pump can be accessed from inside the dishwasher.
1 Cut the power to the dishwasher by unplugging the unit from
the power outlet.
2 Remove the coarse filter and pipe section.
3 Remove the small yellow drain pump access cover at the left
of the bottom drain (see illustration below).
4 By inserting your finger into the hole, you can turn the pump
blades to release anything blocking the pump.
5 Reinstall the access cover and filters.
6 Plug the machine in again.
If the dishwasher still does not start and a whirring sound is
heard, the overflow protection has been triggered.
Shut off the water.
Unplug the unit from the power outlet.
Call the Customer Care Center.
NOTE!
Do not forget to reinstall the drain pump access cover.
Lower spray arm
Holes and bearings can sometimes become blocked.
1 Pull the lower spray arm straight up to release it.
2 Remove any debris using a needle, toothpick, or some other
similar pointed device. The spray arms also have holes
underneath.