Omron EJ1 User Manual page 220

Modular temperature controller
Hide thumbs Also See for EJ1:
Table of Contents

Advertisement

Parameter List
Variable
Category Add-
type
ress
D5 (95)
Can be
0100
Input Digital Filter - CH1
changed
0101
Input Value 1 for Input Correction - CH1
during
operation.
0102
Input Shift 1 - CH1
0103
Input Value 2 for Input Correction - CH1
0104
Input Shift 2 - CH1
0105
MV at PV Error - CH1
Standard Control:
Heating and Cooling Control:
0106
MV at Stop - CH1
Standard Control:
Heating and Cooling Control:
Not used.
0109
MV Upper Limit - CH1
Standard Control:
Heating and Cooling Control:
010A MV Lower Limit - CH1
Standard Control:
Heating and Cooling Control:
010B Hysteresis (Heating) - CH1
010C Hysteresis (Cooling) - CH1
010D Alpha - CH1
010E Manual MV - CH1
Standard Control:
Heating and Cooling Control:
010F SP Upper Limit - CH1
0110
SP Lower Limit - CH1
0111
Disturbance Gain - CH1
0112
Disturbance Time Constant - CH1
0113
Disturbance Rectification Band - CH1
0114
Disturbance Judgment Width - CH1
Not used.
0200
Input Digital Filter - CH2
0300
Input Digital Filter - CH3
0400
Input Digital Filter - CH4
Note The decimal point position is determined by the sensor selection. With analog inputs, the decimal point
position is determined by the Decimal Point Position parameter setting. In this case, however, the 0 (****)
decimal point position setting will be treated as a setting of 1 (***.*).
Variable
Category Add-
type
ress
D6 (96)
Can be
0100
Heater Burnout 1 Detection
changed
0101
HS Alarm 1
during
operation.
0102
Heater Overcurrent 1 Detection
Not used.
0200
Heater Burnout 2 Detection
Variable
Category Add-
type
ress
D7 (97)
Can be
0004
Programless Upload Settings 4
changed
0005
Programless Upload Settings 5
during
operation.
0006
Programless Upload Settings 6
012F Programless Upload Settings 303
Parameter name
H' 00000000 to H' 0000270F (0.0 to 999.9)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
H' FFFFFFCE to H' 0000041A (−5.0 to 105.0)
H' FFFFFBE6 to H' 0000041A (−105.0 to 105.0)
H' FFFFFFCE to H' 0000041A (−5.0 to 105.0)
H' FFFFFBE6 to H' 0000041A (−105.0 to 105.0)
H' FFFFFFCE to H' 0000041A (−5.0 to 105.0)
H' 00000000 to H' 0000041A (−0.0 to 105.0)
H' FFFFFFCE to H' 0000041A (−5.0 to 105.0)
H' FFFFFBE6 to H' 00000000 (−105.0 to 0.0)
H' 00000001 to H' 0000270F (1 to 9999)
H' 00000001 to H' 0000270F (1 to 9999)
H' 00000000 to H' 00000064 (0.00 to 1.00)
H' FFFFFFCE to H' 0000041A (−5.0 to 105.0)
H' FFFFFBE6 to H' 0000041A (−105.0 to 105.0)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
H' FFFFFF9C to H' 00000064 (−1.00 to 1.00)
H' 00000001 to H' 0000270F (0.01 to 99.99)
H' 00000000 to H' 0000270F (0 to 9999)
H' FFFFF831 to H' 0000270F (−1999 to 9999)
The rest are the same as channel 1.
Parameter name
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
The rest are the same as from Heater Burnout Detection 1 to Heater Overcurrent Detection 1.
Parameter name
Setting (monitor) range
Setting (monitor) range
Setting (monitor) range
Appendix
Defau-
Unit
Attribut-
Target Unit
lt
es
TC4/
HFU
TC2
0.0
Seconds ch
---
0
EU
ch
---
0
EU (See
ch
---
note.)
1000
EU
ch
---
0
EU (See
ch
---
note.)
0
%
ch
---
0
%
ch
---
105.0
%
ch
---
−105.0 %
ch
---
10
EU (See
ch
---
note.)
10
EU (See
ch
---
note.)
0.65
---
ch
---
0
%
ch
---
9999
EU
ch
---
−1999
EU
ch
---
0.65
---
ch
---
1.00
Seconds ch
---
0
EU (See
ch
---
note.)
0
EU (See
ch
---
note.)
TC4
---
TC4
---
Defau-
Unit
Attribut-
Target Unit
lt
es
TC4/
HFU
TC2
0.0
A
IO
TC2
---
100.0
A
IO
TC2
---
100.0
A
IO
TC2
---
Defau-
Unit
Attribut-
Target Unit
lt
es
TC4/
HFU
TC2
0900
---
NUM
---
0B00
---
NUM
---
00FF
---
NUM
---
00FF
---
NUM
---
199

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents