Epson Stylus NX100/105/SX100/105/TX100/101/102/103/105/106/109/ME 300/ME OFFICE 360/NX110/115/SX110/115/TX110/111/112/113/115/117/119

4.5.11 CR Unit

Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire
(p
68), Scanner Unit
Panel Unit
(p
72), Printhead
(p
76), CR Motor/ Driven Pulley
Ink System
(p
85), Hopper
(p
80), Main Board
Removal procedure
1.
Release the FFC from the Holder FFC, and pull out the FFC through the hole
of the Main Frame.
Main Frame
Figure 4-79. Removing the CR Unit (1)
DISASSEMBLY/ASSEMBLY
(p
70), Middle Housing
(p
71)
(p
83)
(p
73)
Holder FFC
FFC
Disassembling the Printer Mechanism
2.
Remove the Main Frame. (See
"4.5.9 Main Frame
3.
Slide the CR Unit in the direction of the arrow, and remove it from the Main
Frame.
Main Frame
Figure 4-80. Removing the CR Unit (2)
4.
Remove the CR Encoder FFC from the CR Encoder Connector.
5.
Pull out the Head FFC through the hole of the Carriage, and remove the Head
FFC.
Rib
CR Encoder Connector
Figure 4-81. Removing the CR Unit (3)
Revision C
(p92)".)
CR Unit
CR Encoder FFC
Carriage
Head FFC
Hole