Symptom
Feed system fails to start.
Appliance fails to shut off.
Convection blower fails
to start
Exhaust blower fails to
start or does not shut off.
Large, lazy flame, orange
color. Black ash on glass.
Nuisance shutdowns.
Appliance calls for heat.
Call light illuminates.
Exhaust blower starts.
No feed or igniter.
Hopper lid not closed all
the way
24
Possible Cause
Out of fuel.
#2 snap disc may be defective.
Vacuum switch not closing. No vacuum.
Feed system jammed or blocked.
Feed spring not turning with feed motor.
Feed motor defective or not plugged in.
Call light on.
#1 snap disc defective.
Blower not plugged in.
Blower is defective.
Control box is defective.
Blower not plugged in.
Blower is clogged with ash.
Blower is defective.
Control box is defective.
Dirty appliance.
Poor fuel quality, high ash content.
Fire
pot
clean-out
completely closed.
Excessive amount of fuel.
Low flame.
Sawdust buildup in hopper.
Feed motor is reversing.
Defective thermocouple.
Defective control box.
Fire pot more than 1/2 full.
Thermocouple is defective or not properly
plugged in.
Defective control box
Switch or magnet is out of adjustment
(auger will not function)
Check hopper, fill with fuel.
Replace snap disc. Firebox door must be closed securely.
Check exhaust blower is plugged in and operating.
Check vacuum switch is plugged in. Check vacuum hose is in
good condition, clear and connected at both ends.
Check thermocouple is in good condition and plugged
in properly.
Make sure venting system is clean.
NOTE: High winds blowing into the venting system can
pressurize the firebox causing loss of vacuum.
Empty hopper of fuel. Use a wet/dry vacuum cleaner to remove
remaining fuel, from hopper, including feed tube.
Check feed chute for obstructions.
Loosen 2 screws and jiggle feed assembly.
Check that set screw is tight on feed spring shaft at end of feed
motor.
Check connections on feed motor, replace if defective.
Turn thermostat off.
If call light does not go out, disconnect thermostat wires
from appliance. If call light does go out, thermostat or wires
are defective.
Replace snap disc.
Check that blower is plugged into wire harness.
Replace blower.
Replace control box.
Check that blower is plugged into wire harness.
Clean exhaust system.
Replace blower.
Replace control box
Clean appliance, including fire pot, heat exchangers and
venting system. Remove stainless steel baffle from firebox to
clean ash from on top of baffle. Clean behind rear brick panels.
Change fuel brand to premium.
plate
not
Check that fire pot clean-out plate is fully closed.
Reduce feed rate using feed rate adjustment control rod
located inside hopper.
Increase feed by opening feed rate adjustment control rod
located inside hopper.
Clean hopper, see Cleaning The Hopper on
Check for good connections between feed motor and
wire harness.
Replace thermocouple.
Replace control box.
See High Ash Fuel Content Management on
Check connections on thermocouple or replace if defective.
A flashing yellow light on the control box indicates a problem
with the thermocouple.
Replace control box.
Close the lid. If that doesn't work, adjust or replace the switch
or magnet
7027-802K
Corrective Action
page
19.
page 22
10/21