Vertical Stainless Deflector Replacement

1. Remove 2 front secondary air tubes / vermiculite baffles as per page 22.
2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical deflector.
3. Repeat steps to install new vertical deflector.
NOTE: ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO
TOP OF FIREBOX.
7/16'' Bolts
Slide left + down to remove.
Reverse to replace.
Remove 2 front air tubes
7/16'' Nuts
Vertical Deflector
F2450M Regency Freestanding Woodstove