Technical Data; Cool Mode Performance Data - Panasonic CS-HZ9RKE-1 Service Manual

Table of Contents

Advertisement

19. Technical Data

Technical data provided are based on the air conditioner running under free frequency.

19.1 Cool Mode Performance Data

Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
19.1.1
CS-HZ9RKE-1 / CU-HZ9RKE-1 CS-HZ9RKE-5 / CU-HZ9RKE-5
CS-AZ9RKE-1 / CU-AZ9RKE-1
Indoor (°C)
DB
WB
19.0
27
22.0
15.7
23
18.4
13.3
20
15.8
(Dry bulb value based on 46% humidity)
19.1.2
CS-HZ12RKE-1 / CU-HZ12RKE-1
Indoor (°C)
DB
WB
19.0
27
22.0
15.7
23
18.4
13.3
20
15.8
(Dry bulb value based on 46% humidity)
TC
- Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP
- Input Power (kW)
16
TC
SHC
IP
2990
2659
254
3337
2012
240
2840
2583
266
3075
2050
258
2028
1987
153
2043
1742
141
16
TC
SHC
IP
4186
3331
463
4672
2522
438
3976
3237
485
4305
2569
471
2503
2288
209
2519
1923
197
Outdoor DB (°C)
25
TC
SHC
IP
2810
2528
345
3095
1916
338
2629
2488
352
2800
1902
347
1930
1892
254
2524
1844
349
Outdoor DB (°C)
25
TC
SHC
IP
3934
3168
630
4333
2400
616
3680
3118
641
3919
2384
633
2702
2657
464
3534
2310
636
121
35
TC
SHC
IP
2500
2400
455
2719
1756
450
2343
2296
454
2515
1779
454
1834
1798
399
2252
1724
452
35
TC
SHC
IP
3500
3007
830
3807
2200
821
3280
2968
828
3520
2229
828
2568
2542
728
3152
2160
824