Video BW
Reference level offset
Reference level
A power meter with a peak power detector can be also used. Remember to take the attenuations into
account.
7. Adjust power for all bold power levels to correspond the Target dBm column by pressing + or – keys.
8. If all bold power levels are adjusted, click Next to continue with GSM900 EDGE.
9. Adjust power for all bold power levels to correspond the Target dBm column by pressing + or – keys.
Next actions
Continue tuning the bold power levels of the GSM1800 and GSM1900 bands. You will see this message, if
finished successfully:
Page 7 –30
COMPANY CONFIDENTIAL
Copyright © 2007 Nokia. All rights reserved.
RF Troubleshooting and Manual Tuning Guide
3MHz
sum cable attenuation with module jig
attenuation