[44] Access Bypass Mask (Codes 9 to 16)

Program using the same method as section [43].
Note: Zone lights 1 to 8 represent access codes 9 to 16.

[45] TLM Restoral Reporting Code

Once the code is programmed, the panel will transmit the
reporting code every time that a phone line trouble is
restored. This will also initiate transmission of all codes
unsuccessfully transmitted during the phone line fault.
[46] Downloading Computer Telephone
Number
This is the telephone number that the panel would use to call
the downloading computer if the CALLBACK feature (section
[47]) is enabled or if a user initiated call up is done.
([ ]+[6]+[ Master Code]+[ 9]).

[47] Modem Configuration

[1] - [4] Zone Lights 1 through 4 are used to determine the
number of rings before the system will answer an
incoming call for downloading. Refer to the
Programming Worksheets for information on
programming Zone Lights 1 through 4.
[5] Downloading Answer Enabled / Disabled
ON = Downloading Answer Enabled.
The system will answer calls for downloading after the
number of rings programmed with Zone Lights 1 through 4.
OFF = Downloading Answer Disabled.
The system will not answer incoming calls. With
Downloading Answer disabled, downloading must be
performed with the User Call-up or Periodic Downloading
functions.
[6] User Call-up Enabled / Disabled
ON = User Call-up Enabled.
The user can have the system call the downloading
computer by entering the [ ][6][Master Code][9]
Command. For the User Call-up Command to function, a
Downloading Computer Telephone Number and a Panel
Identification Code need to be programmed.
OFF = User Call-up Disabled.
[7] Answering Machine Over-ride Enabled / Disabled
ON = Answering Machine Over-ride Enabled.
The system may be connected to the same telephone line
as an answering machine. To over-ride the answering
machine, have the downloading computer call the system
and let the telephone line ring only once or twice. After one
or two rings, hang up. If the system is called back within the
time set in section [51] with Zone Light 7, the system will
answer the next call on the first ring. Refer to section [51]
Third System Option Code, Light 7 Answering Machine
Over-ride Timer Option.
WWW.DIYALARMFORUM.COM
OFF = Answering Machine Over-ride Disabled. The
system will only answer incoming calls after the number
of rings programmed with Zone Lights 1 through 4.
[8] Downloading Call Back Enabled / Disabled
ON = Downloading Call Back Enabled.
When the system answers the downloading computer's
call, both the computer and the system will hang up.
The system will then call the Downloading Telephone
Number and connect with the computer at that number.
If more than one downloading computer is to be used,
this function should be disabled.
OFF = Downloading Call Back Disabled.
The downloading computer will have immediate access
to the system once the system is identified as a valid
system.

[48] Panel Identification Code

Program using the same method as sections [24], [25] and
[26].

[49] 4th System Option Code

[1] For Future Use.
Note: Zone Light 1 must be OFF at all times.
[2] Fire Zone Connection Options
ON = Fire Zone Connected to SW AUX.
Smoke detectors on the Fire Zone are powered from the
SW AUX terminal. When the [ ][4] Command is entered,
power will be removed from the smoke detectors to allow
them to be reset. When the [ ][4] Command is used, the
Fire Zone Trouble normally generated from a power
supervision relay when power is removed from the
smoke detector is not displayed or communicated.
OFF = Fire Zone Not Connected to SW AUX.
Smoke detectors on the Fire Zone are not powered from
the SW AUX terminal. If the [ ][4] Command is entered,
Trouble Condition 4 (Fire Zone Trouble) will be displayed
and reported to the monitoring station.
[3] Escort Access Code Options
ON = Escort Requires Master Code.
The Escort Voice Assisted Security Control Module will
only allow remote access to the system if the Master
Code is entered.
OFF = Escort Accepts Any Access Code.
The Escort Voice Assisted Security Control Module will
allow remote access to the system for any valid Access
Code.
[4] For Future Use.
[5] For Future Use.
[6] For Future Use.
[7] For Future Use.