Programming Guide; Introduction; Reviewing Programmed Data; Binary Programming - DSC PC3000 Installation Manual

Hide thumbs Also See for PC3000:
Table of Contents

Advertisement

PROGRAMMING
GUIDE

Introduction

The PC3000 is programmed by entering instructions from the
panel keypad. The PC3000 memory is EEPROM and can be
reprogrammed thousands of times. The EEPROM will not
lose memory even on total AC and battery failure. All
essential program information required to define the
operation of the control panel and the communicator is
stored in a section of the EEPROM which can only be
accessed using the Installer's Programming Code. If the
code is forgotten, the default program code can be re-
inserted by using the "Hardware Reset" described on page
22, unless Installer's Lockout is enabled. See sections [90]
and [91].
To begin programming the PC3000, enter [ ], [8], [3000]
while the panel is disarmed. Installer's Programming can
only be done while the panel is disarmed and not in alarm.
The factory default Installer's Programming Code is [3000].
This default code can be changed using the Section [24]
command listed below (new Installer's Code). Once the
basic Installer's command is entered ([ ] [8] [3000]) the
"Program" light will start to flash. The "Program" light will
continue to flash while programming. Note that while
programming, if no key entry is made for more than 2
minutes, the keypad will return to the arm-disarm mode and
the complete installer's command ([ ] [8] [3000]) must be
entered before programming can resume.
The next step is to enter a 2 digit section entry for any of the
commands described in the following pages. Note that while
the keypad is waiting for the section entry the "Armed" light
is on steady. As soon as the 2 digits are entered for the
section the keypad will beep 3 times, the "Armed" light will
go out and the "Ready" light will go on. The keypad is then
ready to accept data entry for the selected section.
A complete description of each programming section will be
given in the remaining pages of this section. A programming
work sheet summarizing all programming commands is
provided in the next section of the manual. Fill out the work
sheet and use it as a guide when programming.
As the required data for a programming section is entered,
the hexadecimal value of the information in that location is
displayed on zone lights 1-15. Most sections contain several
groups of two digit entries. The keypad beeps twice and the
"Armed" light flashes after each group of two digits is
entered. When the required data is completely entered for
the section being programmed, the keypad will beep 5 times
and the "Armed" light will come back on to indicate that the
expected data has been entered and another section can be
selected for programming. After completing one section, it is
not necessary to re-enter the [ ] [8] [Installers' code] portion
of the command. Just enter the number of another
programming section. When programming a section, it is
possible to exit by pressing [#]. Only the data entered before
pressing [#] will be changed in the EEPROM. Practice
entering data in several sections until you become familiar
with the programming commands.
WWW.DIYALARMFORUM.COM
Certain programming entries may require "HEX" data. That is
the numbers 0 through 9 and the letters A through F (in
"HEX" numbering the letters A...F represent the numbers
10...15). Where commands require "HEX" data A-F, first
press [ ]. The keys 1-6 now assume the hex values A-F and
the "Ready" light begins to flash. Key 1 = A, Key 2 = B, Key
3 = C, Key
4 = D, Key 5 = E and Key 6 = F. Pressing the [ ] again stops
the "Ready" light from flashing and the keys assume the
normal values for the numbers from 1 to 9. The most
common mistake in entering "HEX" data is forgetting to press
[ ] again after entering the "HEX" digit to return to normal
number entry.
The data for sections 18, 19, 20, 21, 29, 30, 31, 32, 43, 44,
47, 49 and 51 is entered using the keypad zone lights to
indicate which functions are active and the number keys to
turn functions on and off. When the section number is
entered, the zone lights 1...8 will display which functions are
currently on. Pressing the number key corresponding to the
zone light alternately turns the function on and off. All
functions can be turned off by entering [0]. When the correct
selections have been made press [#] to record them in
memory and to go on to program the next section.

Reviewing Programmed Data

Enter the section you wish to review by entering the 2 digit
section number. The zone LED's will represent the value
(hexadecimal format) of the first digit in that section. Each
press of the 'F' key will advance the display to the next digit.
At the end of the section, the keypad buzzer will beep
several times and return you to the program mode where
another section can be selected for review or programming.
Note: Only sections [01] through [17], [22] through [28],
[33], [45], [46], [48], [50] and [52] through [54] can be
reviewed using the above method.

[00] Binary Programming

This section is normally used upon instruction from factory
technical personnel for specialized programming not
covered by the standard programming instructions.
13

Advertisement

Table of Contents
loading

Table of Contents