PROGRAMMING GUIDE

With the panel disarmed, enter [
disarmed. The default Installer's Code is [0560]. The Installer's Code should be changed after the system is
installed; refer to Programming Section [03].
When the Installer's Programming Command is entered, the "Armed" light will come ON and the "System" light
will FLASH to indicate that the panel is ready for programming. NOTE: If no key entry is made for 2 minutes,
the panel will return to the "Ready" mode and the Installer's Programming Command will have to be entered
again.
With the "Armed" light ON and the "System" light flashing, enter 2 digits for the Section to be programmed. The
Programming Sections are numbered from [01] to [15], and each section is programmed independently.
Once the 2 digits for the section to be programmed are entered, the keypad will beep 3 times; the system is
now ready to accept data for the selected section. In sections that contain groups of 2-digit numbers, the
keypad will beep twice after each 2-digit number is entered.
To change the first digit in a section, enter a new digit from the keypad. If you wish to keep the first digit
unchanged, enter the same number.
When all data for the section is completely entered, the keypad sounder will beep several times to indicate that
all expected data has been entered. When a section is completely programmed, enter the number of the next
section to be programmed.

Sections [05] through [07]: Enabling System Functions

These sections allow you to enable or disable various system functions. Refer to the Programming Worksheets
to see which functions are represented by the Zone Lights.
To enable or disable a feature, press a number from 1 to 4 to turn the corresponding zone light ON or OFF. When
all selections have been made, press the [#] Key to save the changes and return to the program mode.

HEX Data Programming

Certain programming entries may require the entry of data in HEX (hexadecimal, or base 16) format. HEX
numbering uses the digits 0 through 9 and the letters A through F.
The letters A through F are represented by the number keys 1 through 6. To enter data in HEX format, first press
the [
] Key. The "Ready" and "System" lights will FLASH. Enter the HEX value, then press the [
to return to the normal data entry mode; the "Ready" light will stop flashing, and the "System" light will continue
to flash.
To enter HEX numbers:
] before and after each digit. The last digit in each section does not require the final asterisk (
Enter [
be entered.
][8][Installer's Code]. The panel can only be programmed while it is
A
Enter
B
Enter
C
Enter
D
Enter
E
Enter
F
Enter
[
][1][
]
[
][2][
]
[
][3][
]
[
][4][
]
[
][5][
]
[
][6][
]
] Key again
) to
11