Mounting The Indoor Unit; About Mounting The Indoor Unit; Precautions When Mounting The Indoor Unit; To Install The Indoor Unit - Daikin Altherma 3 H MT ECH2O Installer's Reference Manual

Hide thumbs Also See for Altherma 3 H MT ECH2O:
Table of Contents

Advertisement

7
|
Unit installation

7.4 Mounting the indoor unit

7.4.1 About mounting the indoor unit

7.4.2 Precautions when mounting the indoor unit

7.4.3 To install the indoor unit

7.4.4 To connect the drain hose to the drain

Installer reference guide
82
Typical workflow
Mounting the indoor unit typically consists of the following stages:
1
Installing the indoor unit.
INFORMATION
Also read the precautions and requirements in the following chapters:
"2 General safety
"7.1 Preparing the installation
1 Lift the indoor unit from the pallet and place it on the floor. Also see
handle the indoor
2 Connect the drain hose to the drain. See
4
the
drain" [
 82].
3 Slide the indoor unit into position.
NOTICE
Level. Make sure the unit is level.
Spillover water from the water storage tank as well as water collecting in the drain
pan must be drained. You must connect the drain hoses to an appropriate drain
according to the applicable legislation.
1 Open the screw plug.
5
6
4
precautions" [
 10]
4
site" [
 66]
4
unit" [
 26].
"7.4.4 To connect the drain hose to
EPRA08~12EAV3+W1 + ETSH/X(B)12P30+50EF