Install Upper Flue Mounting Bracket; Install The Hood - Broan EWP1306SS Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALL UPPER FLUE MOUNTING
BRACKET
Center of installation
Recommended
distance between
screw holes
21⁄
Ceiling
installation
HD1175
Upper flue mounting
bracket slots
HD1176
1. If a framing member is not present, drill two 5/16" diameter
holes where shown. Insert drywall anchors into the holes.
2. Center the bracket over the hood location and flush with the
ceiling. Make sure that the slots of the upper flue bracket are
at the bottom. Secure the upper flue bracket to the wall using
(2) no. 8 x 1½" mounting screws.
3. Tighten the screws completely. Make sure that the bracket
is tight against the wall.
Ceiling
C L
1"
4¼"
Ø 5/16" TYP.
"
8
Flush with
Center of
the ceiling
C L
MODELS EWP1306SS • EWP1366SS

INSTALL THE HOOD

(Horizontally Ducted Hoods Only)
1. DO NOT REMOVE the protective plastic film covering the
decorative flue and the hood at this time.
2. Lay the back side of the hood flat on a table. Use a piece of
cardboard to avoid damaging the table or the hood.
3. Remove the grease filters by pulling down the metal latch
tab and tilting filters downward to remove.
4. Carefully rotate hood upright.
LOWER FLUE
MOUNTING BRACKET
5. To make sure there will be adequate clearance between top
of hood and lower flue mounting bracket for ductwork: Elbow
must be located below lower flue mounting bracket.
6. Align the hood and center it above the hood mounting
bracket. Gently lower the hood until it securely engages the
bracket.
INSIDE BACK OF HOOD
SIDE VIEW
HOLES LOCATION
7. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5/16" drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) no. 8 x 1½"
mounting screws through the hood back and into the drywall
anchors. Verify that the hood is centered and leveled.
Tighten all screws completely.
8. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Pull down the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.
Page 6
14¼"
MAX.
MOTOR/BLOWER
ASSEMBLY
Ø 5/16" TYP.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewp1366ss

Table of Contents