5.5 Output specification

Item
Signal name
Y0 to Y5
Circuit isolation
By photocoupler
Operation indi-
LED is lit while output is ON
cation
External power
5
supply
Load current
50mA or less
Open circuit
0.1mA
leak current
Output ON volt-
0.5V max
age
0.2ms max. for both OFF→ON and
Response time
ON → OFF.
Guidelines for the safety of the user and protection of the FX

POSITIONING CONTROLLER

This manual has been written to be used by trained and competent personnel. This is defined
by the European directives for machinery, low voltage and EMC.
If in doubt at any stage during the installation of the FX
electrical engineer who is qualified and trained to the local and national standards. If in doubt
about the operation or use of the FX
distributor.
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential
damage that may arise as a result of the installation or use of this equipment.
All examples and diagrams shown in this manual are intended only as an aid to understand-
ing the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for
actual use of the product based on these illustrative examples.
Owing to the very great variety in possible application of this equipment, you must satisfy
yourself as to its suitability for your specific application.
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any
patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving
industrial property rights which may occur as a result of using the contents noted in this manual.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN
JY992D77701D
General-purpose output
24V DC ± 10%
to
24V DC or less
/
Manual number : JY992D77701
Manual revision : D
Date
FP , RP, CLR
By photocoupler
LED is lit while output is ON
5
to
20mA or less
0.1mA/24V DC or less
0.5V max (CLR is 1.5V max.)
Pulse output FP RP is 200kHz max.
Pulse output width of the CLR signal:
Approx. 20msec.
-10GM always consult a professional
2N
-10GM please consult the nearest Mitsubishi Electric
2N
: November 2008
Output to drive unit
24V DC ± 10%
-10GM
2N
Effective Nov. 2008
Specifications are subject to
change without notice