INSTALLER SETUP MENU
Settings
This setting will flash FILT in
the display after the elapsed
run time to remind the user
Filter Change
to change the filter. The OFF
Reminder
setting will disable this feature.
This setting allows the installer
to change the calibration of
Room
the room temperature display
Temperature
so that, for example, the
Calibration
thermostat would read 72°F
instead of 70°F.
The installer can select the
Minimum
minimum run time for the
Compressor
compressor to help protect the
On-Time
compressor from short-cycling.
14
Display
Adjustment Options
The filter change reminder
can be adjusted from OFF
Next step
to 2000 hours in 50 hour
increments. Press the
second button from the top
left side of the thermostat
to display the current filter
Prev step
elapsed run time.
Next step
The room temperature display
can be adjusted to read 3°
above or below the factory
calibrated temperature.
Prev step
The minimum compressor
run time can be adjusted
Next step
from OFF to 3, 4, or 5
minutes. If 3, 4, or 5 is
selected, the compressor
will run for at least the
Prev step
selected time before
turning off (although the
fan may continue to run
for a short time).
Default
OFF
0
OFF