KM-1301S_J
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
The transformer's voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.
208-230/60/1
JUNCTION BOX
BLACK
L1
BROWN
L2
4A5812-010
KM-1601S_J
KM-1900S_J
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage
to the icemaker. The white lead
must be connected to the neutral
conductor of the power source.
See diagram below.
208-230/60/1
(3 wire with neutral for 115V)
JUNCTION BOX
L1
BLACK
N
WHITE
L2
BROWN
4A5700-010
Fig. 7
23
KM-1301S_J3
KM-1601S_J3
KM-1900S_J3
KM-2100S_J3
KM-2500S_J3
WARNING
ELECTRICAL CONNECTION
THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
This unit must be connected to a
three-phase power source.
The transformer's voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.
JUNCTION BOX
208-230/60/3
L1
BLACK
L2
BROWN
L3
RED
4A5701-010