OPERATION AND MAINTENANCE GUIDELINES

WARNING: Do not slam or strike doors. Damage
can result in a hazardous condition.
WARNING: Discontinue use of the appliance imme-
diately if doors are damaged and contact a qualified
installer for repair. Only doors certified with the ap-
pliance shall be used.
Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water. Do
not use any abrasive material to clean glass. Do not clean glass with any
cool water if glass is still hot from the fire and smoke.
Doors Fully Closed
Fireplace Front
Doors Fully Opened
Fireplace Front
Figure 40 - Bi-Fold Glass Doors
OUTSIDE AIR AND DAMPER HANDLE OPERATION
The damper handle, which opens and closes the damper blade, is
located in the upper front face of the fireplace. Pushing the handle
forward and up through the keyway slot will free damper blade to
automatically open. Pushing the handle forward and down will lock
damper blade closed (see Figure 41).
full open position before operating fireplace
To Close
Damper
To Open
Damper
Figure 41 - Operating Damper Handle
127017-01_H
Damper must be locked in the
(see Figure 41).
Damper
Weight
Damper
Weight
SuperiorFireplaces.us.com
IMPORTANT NOTICES - CANADA
IMPORTANT NOTICE
A manufactured shroud which has been approved by a
national testing agency for use with this fireplace may
be used if installed in accordance with the instructions
by its manufacturer. A locally fabricated shroud may be
used with IHP Shroud Leg Spacer Kit (SLK) in accor-
dance with instructions provided with the shroud.
NOTICE: The firebox canopy (hood) must not be mod-
ified or replaced with a canopy that may be provided
with the unvented decorative room heater.
CAUTION: THE STRUCTURAL INTEGRITY OF THE
MANUFACTURED HOME FLOOR, WALL, AND CEIL-
ING/ROOF MUST BE MAINTAINED.
WARNING: DO NOT INSTALL IN SLEEPING ROOM
OF MOBILE HOMES.
Canadian code CAN/ULC-S610-M87 and other pertinent codes require stain-
less steel chimney for the installation of this fireplace. A Cold Air Climate Kit is
also required in Canada and is recommended for cooler regions in the United
States. Below, find a list of approved stainless steel parts.
Chimney Parts List for Canada
Catalog
Model
12" Hi-Temp
No.
No.
Wood-burning Chimney
F0953
12-12HT
12" Section Double Wall Pipe
F0954
18-12HT
18" Section Double Wall Pipe
F0955
24-12HT
24" Section Double Wall Pipe
F0956
36-12HT
36" Section Double Wall Pipe
F0957
48-12HT*
48" Section Double Wall Pipe
F0958
30E-12HT
30" Offset and Return
F0959
12S-12HT
Chimney Support
F0960
RLT-12HT* Round Top w/ Louvers
F0961
AP-12HT
Anchor Plate/Collar Assembly (Masonry Fireplaces)
F0951
CAK-12
Cold Air Collar Kit
*When ordered alone, this part cannot ship via parcel delivery services.
19