Drl**13 (N/L) I-2 Wiring Diagram; Installation Of Electrical Supply - Montigo DelRay DRL3613NI-2 Installation & Maintenance Manual

Indoor direct vent gas fireplace
Hide thumbs Also See for DelRay DRL3613NI-2:
Table of Contents

Advertisement

DRL**13 (N/L) I-2 Wiring Diagram
BATTERy PACK
1.5V AA tYPe
1.5V AA type
1.5V AA tYPe
1.5V AA type
1.5V AA tYPe
1.5V AA type
red
1.5V AA tYPe
1.5V AA type
BLACK
885 proflame
pilot
burner
MODEL
drl3613*i-2
DRL4813*I-2

Installation of Electrical Supply

installations in canada must be electrically grounded in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
installations in the usA must be grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70.
NOTE: If any of the original wire supplied with the appliance is replaced,
it must be replaced with the same type, or its equivalent.
18
SPARK
sensor
MAIN ON/OFF
switch
yellow/green
orange
green
led lights
led1 - red led
led2 AMber led
Figure 17. Wiring diagram for DRL3613NI-2 with SIT Proflame Electronic Ignition
X2
X1
X3
X4
X5
X10
X11
Installation
green
MAin Power
white
120vac 60 hz
6 amps
black
VAriAble sPeed
coMFort FAns
BLACK
110V
bV
white
red
red
trAnsForMer
hAlogen lights
bulb type
g4 socket
12v 10w
xg0226 - 042220