Section 4: Wiring

DRL**13 (N/L) I Wiring Diagram
MODEL
drl3613*i
DRL4813*I

Installation of the wall switch

Montigo supplies 15' of low voltage wire to be plugged into the control
board. Connect to a standard single pole ON/OFF switch to the location
of your choice. You may extend these wires up to 30' in length with a
wire of equal quality.
installations in canada must be electrically grounded in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes.
installations in the usA must be electrically grounded in accordance
with local codes or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70.
optional remote control available through your Montigo dealer.
xg0226 - 042220
SPARK
X2
SENSOR
X3
TO ON/OFF
BLUE
X4
RE
WALL SWITCH
6
BLUE
WHITE
OPTIONAL CPI/IPI SWITCH
X5
YELLOW/GREEN
ORANGE
10
GREEN
Figure 15. Wiring diagram for DRL3613NI with SIT Proflame Electronic Ignition
GREEN
WHITE
X1
BLACK
Main Power
To PPO
120VAc 60hz
6 amps
Installation
17