Cal Spas A726B Pre-Delivery Manual page 16

Cal spas spa owner's manual
Hide thumbs Also See for A726B:
Table of Contents

Advertisement

Spa Model
All 230V spas (except
6205 control boxes
requiring high amperage
- see below)
Spas with the 6300
control box (when high
amperage is selected on
circuit board)
SEE CONFIGURATION
INSTRUCTIONS ON
NEXT PAGE.
Ultimate Fitness spas
with one 5.5 kW heater
Ultimate Fitness spas
with two 5.5 kW heaters
Designer in-ground spas
with one 3 kW heater
Designer in-ground spa
with one 3 kW heater
and one 5.5 kW heater
Testing the RCD Breaker
Test the RCD breaker prior to first use and periodically when the spa is
powered. To test the RCD breaker follow these instructions (spa should
be operating):
1.
Press the TEST button on the RCD. The RCD will trip and the spa will
shut off.
2.
Reset the RCD breaker by switching the breaker to the full OFF position,
wait a moment, then turn the breaker back on. The spa should have
power again.
14
GFCI Required
One 32 amp RCD
or two 16 amp
RCDs
One 32 amp RCD
or two 16 amp
RCDs
One 32 amp RCD
or two 16 amp
RCDs
Service 1: One 32
amp RCD or two 16
amp RCDs
Service 2: One 32
amp RCD or two 16
amp RCDs
One 32 amp RCD
or two 16 amp
RCDs
Service 1: One 32
amp RCD or two 16
amp RCDs
Service 2: One 32
amp RCD or two 16
amp RCDs
Wires Required
Four #10 AWG
copper wires
Four #10 AWG
copper wires
Four #10 AWG
copper wires
Service 1: Four #10
AWG copper wires
Service 2: Three #10
AWG copper wires
Four #10 AWG
copper wires
Service 1: Four #10
AWG copper wires
Service 2: Three #10
AWG copper wires

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents