Table 2 Electrical Specifications - Bard Q-TEC Q24H3DA Installation Instructions Manual

Packaged heat pump
Hide thumbs Also See for Q-TEC Q24H3DA:
Table of Contents

Advertisement

No.
Rated Volts
Field
MODEL
& Phase
Power
Circuits
Q24H3DA0Z
1
A05
230/208-1
1
A10
1 or 2
Q24H3DB0Z
1
B06
230/208-3
1
B09
1
Q24H3DC0Z
1
C06
460-3
1
C09
1
Q30H3DA0Z
1
A05
230/208-1
1
A10
1 or 2
Q30H3DB0Z
1
B06
1
230/208-3
B09
1
B12
1
Q30H3DC0Z
1
C06
1
460-3
C09
1
C12
1
Q36H3DA0Z
1
A05
1
230/208-1
A10
1 or 2
 A15
1 or 2
Q36H3DB0Z
1
B06
1
230/208-3
B09
1
 B15
1
Q36H3DC0Z
1
C06
1
460-3
C09
1
 C15
1
Q43H3DA0Z
1
A05
1
230/208-1
A10
1 or 2
 A15
1 or 2
Q43H3DB0Z
1
B06
1
230/208-3
B09
1
 B15
1
Q43H3DC0Z
1
C06
1
460-3
C09
1
 C15
1
Q48H3DA0Z
1
A05
1 or 2
230/208-1
A10
1 or 2
 A15
1 or 2
Q48H3DB0Z
1
B06
1
230/208-3
B09
1
 B15
1
Q48H3DC0Z
1
C06
1
460-3
C09
1
 C15
1
Q60H3DA0Z
1
A05
1 or 2
230/208-1
A10
1 or 2
 A15
1 or 2
Q60H3DB0Z
1
B09
230/208-3
1
 B15
1
Q60H3DC0Z
1
C09
460-3
1
 C15
1
 Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest
revision), article 310 for power conductor sizing.
CAUTION: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to
Note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway.
 Maximum KW that can operate with heat pump on is 10KW. Other 5KW energizes during emergency heating only.
 Maximum KW that can operate with heat pump on is 9KW. Other 6KW energizes during emergency heating only.
NOTE: Reference Form 7960-582 for dehumidification model performance information.
TABLE 2 – Electrical Specifications
Single Circuit
Maximum
Minimum
Field
External
Circuit
Power
Fuse or Ckt.
Ampacity
Wire Size
Brkr.
22
30
10
47
50
8
72
80
4
17
20
12
35
35
8
44
45
8
10
15
14
19
20
12
23
25
10
27
35
8
52
60
6
77
80
4
19
25
10
38
40
8
47
50
8
56
60
6
13
15
14
22
25
10
26
30
10
31
35
8
29
40
8
55
60
6
79
80
4
82
90
4
21
30
10
39
45
8
48
50
8
52
60
6
13
15
14
22
25
10
27
30
10
27
30
10
31
45
8
57
60
6
81
90
4
81
90
4
26
35
8
44
50
8
53
60
6
53
60
6
13
15
14
22
25
10
27
30
10
27
30
10
37
50
8
62
70
6
87
90
3
87
90
3
28
40
8
47
50
8
56
60
6
56
60
6
16
20
12
25
25
10
29
30
10
29
30
10
42
60
8
67
80
4
92
100
3
92
100
3
32
45
8
59
60
6
59
60
6
16
20
12
31
35
8
31
35
8
 Minimum
 Maximum
Circuit
External Fuse or
Ground
Ampacity
Ckt. Breaker
Wire
Ckt. A
Ckt. B
Ckt. A
10
10
8
22
50
30
12
10
10
14
12
10
10
10
8
27
50
30
10
10
10
10
14
10
10
10
10
10
8
29
50
45
8
32
50
45
10
10
10
10
14
10
10
10
10
10
8
31
50
45
8
33
50
45
10
10
10
10
14
10
10
10
10
8
37
25
50
8
37
50
50
8
37
50
50
10
10
10
10
12
10
10
10
10
8
42
25
60
8
42
50
60
8
42
50
60
10
10
10
12
10
10
Dual Circuit
Field Power
Ground
Wire Size
Wire Size
Ckt. B
Ckt. A
Ckt. B
Ckt. A
50
10
8
10
50
10
8
10
50
8
8
10
50
8
8
10
50
8
8
10
50
8
8
10
25
8
10
10
50
8
8
10
50
8
8
10
25
8
10
10
50
8
8
10
50
8
8
10
Manual
2100-653
Page
5 of 44
Ckt. B
10
10
10
10
10
10
10
10
10
10
10
10