Appendix
Code
Parameter
D.058
Solar post-heating
D.060
Number of safety therm.
shut-downs
D.061
No. of shut-downs in ign.
flame controller
D.064
Avg. ignition time
D.065
Max. ignition time
D.067
Remaining anti-cycl. time
for heating
D.068
Number of first start at-
tempts
D.069
Number of second start
attempts
D.070
3-way valve operation
D.071
Max. heating target flow
temp.
D.072
Pump overrun after cylin-
der charging
D.073
Offset setting for comfort
mode
D.074
Anti-legionella funct. with
integrated cyl.
D.075
Max. cylinder charging
time
D.076
Device Specific Number
D.077
DHW partial load
D.078
DHW max. flow temperat-
ure
D.080
Heating operating hours
D.081
DHW operating hours
D.082
Heating burner starts
D.083
DHW burner starts
D.084
Maintenance in
36
Values
Unit
Min.
Max.
0
3
Current value
Current value
Current value
s
Current value
s
Current value
min
Current value
Current value
0
2
40
80
°C
0
10
min
−15
5
K
0
1
20
90
min
Current value
Output-range-
kW
specific
55
80
°C
Current value
h
Current value
h
Current value
Current value
„– – –"
3000
h
Installation and maintenance instructions ecoTEC exclusive 0020189875_01
Increment, select, explanation
Only products with integrated do-
mestic hot water generation
0 = Solar post-heating deactivated
3 = Domestic hot water activated
(min. target value 60 °C)
Number of safety cut-out switch-off
sequences
Unsuccessful ignitions at 1st at-
tempt
Unsuccessful ignitions at 2nd at-
tempt
0 = Normal operating mode
1 = Mid-position (parallel operation)
2 = Permanent heating position
Target value maximum heating flow
temperature
1
Internal pump
1
Only products with integrated do-
mestic hot water generation
1
0: Off
1: On
Max. charging time for domestic
hot water cylinder without inde-
pendent control system
1
(Device specific number = DSN)
Adjustable cylinder charging output
Limit on cylinder charging temper-
ature
1
Note
The chosen value must be at least
15 K above the cylinder target
value.
Number of hours until the next
maintenance
1
"– – –" = Deactivated
Default
Own
setting
setting
0
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
0
75
2
0
1
45
Not ad-
justable
100 %
75
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable