Vaillant ecoTEC exclusive Installation And Maintenance Instructions Manual page 32

Hide thumbs Also See for ecoTEC exclusive:
Table of Contents

Advertisement

Appendix
Setting level
Hydraulic operating mode
Pressure level
Target flow temp.
DHW temperature
Green iQ
Heating partial load
Auxiliary relay
Accessory relay 1
Accessory relay 2
Set the type of gas
Contact details
End the installation assistant?
¹Fault lists are only displayed, and can only be deleted, if faults have occurred.
32
Values
Unit
Increment, select, explanation
Min.
Max.
0
4
0: Without overflow
1: 40% (low loss head.)
2: 60% (low loss head.)
3: 100% (low loss head.)
4: With overflow
100
400
mbar
30
75
1
35
60
1
Product with hot water generation
On, Off
kW
Partial load only, full load only, auto
1
10
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
1
10
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
1
10
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = eBUS remote control (not active)
9 = Legionella protection pump (not active)
10 = Solar valve (not active)
0
2
0: Natural gas
1: Propane 50 mbar
2: Propane 30/37 mbar
Phone number
0-9
Yes, No
Installation and maintenance instructions ecoTEC exclusive 0020189875_01
Default
setting
10
0
200
On
Auto
2
2
2