Installing Your Appliance - Westinghouse WVE606 User Manual

Electric built-in ovens
Hide thumbs Also See for WVE606:
Table of Contents

Advertisement

INSTALLING YOUR APPLIANCE

WARNING
To avoid any potential hazard, you must follow our
instructions when you install your appliance. Failure
to install the appliance correctly could invalidate any
warranty or liability claims and lead to prosecution.
This appliance must be installed by an authorised
person according to all codes and regulations as
stated in the local municipal building code and other
relevant statutory regulations.
Wiring connections must be in accordance with AS/
NZS 3000 Wiring Rules and any particular conditions
of the local authority.
Refer to data plate for rating information. The data
plate is positioned behind the bottom of the oven
door.
Disconnection in the fixed wiring must occur in
accordance with the AS/NZS3000 wiring rules.
Wiring should be protected against mechanical
failure. Refer to AS/NZS3000 clauses 3.3.2.6, 3.9, 3.10
A means of disconnection with a contact separation
of at least 3mm must be supplied in the fixed wiring.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance test
after manufacture. If the resistance reading is low at
installation, it is probably caused by moisture from
the atmosphere being absorbed by the elements
after the range has been produced. (Pass at 0.01MΩ
AS/NZS 3000 Wiring Rules Clause 8.3.6.2).
Rated power input
MODEL
TOTAL kW
WVE645
8.7
PRODUCT
MODEL
DIMENSIONS
(H X W X D) MM
WVE613
597 x 596 x 573
WVES613
597 x 596 x 573
WVE614
597 x 596 x 573
WVE615
597 x 596 x 573
WVE616/606
597 x 596 x 573
WVEP615
597 x 596 x 573
WVE617
597 x 596 x 573
WVEP618
597 x 596 x 573
WVE626
890 x 596 x 573
WVE636
1083 x 596 x 573
WVE645
597 x 596 x 573
WVE655
727 x 596 x 573
WVE665
890 x 596 x 573
WVE607
597 x 596 x 573
Note: Electrical connection is 230-240 volts AC 50Hz. Wiring minimum temperature rating 75°C.
42
INSTALLATION
A1 kW
A2 kW
2.3
6.4
MINIMUM FUSE
RATING
16A
16A
16A
16A
16A
16A
16A
16A
25A
32A
40A
25A
25A
16A
WARNING
This appliance must be properly earthed.
Do not lift the appliance by the door handles.
Prepare the cupboard opening to match your
appliance measurements. (See diagrams)
Slide appliance into the cupboard, ensuring that the
supply cable (where fitted) does not kink.
To prevent tipping, use the screws supplied to secure
your oven into the cupboard. Use just 2 screws for
underbench and separate grill underbench ovens, and
4 screws for separate grill wall ovens. Remove the
bottom door in separate grill wall ovens to provide
access to the bottom 2 screwing points.
For appliances fitted with a flexible supply cord, if
the cord is damaged, it must be replaced by the
manufacturer or its service agent or similarly qualified
person in order to avoid a hazard. The plug must be
accessible after installation.
Where the appliance is built into a cabinet, the
cabinet material must be capable of withstanding
70°C. Installation into low temperature tolerant
cabinetry (e.g. vinyl coated) may result in
deterioration of the low temperature coating by
discolouring or bubbling.
If the appliance is installed adjacent to vinyl-wrapped
surfaces, use an installation kit available from the
vinyl-wrap supplier.
Electrolux Home Products cannot accept
responsibility for damage caused by installation into
low temperature tolerant cabinets.
After installation, test and ensure that the appliance
operates correctly before handing it over to the
customer. It is recommended that this product is not
installed in an unvented living space, particularly if
that space incorporates sleeping quarters.
MAXIMUM
MAXIMUM
POWER RATING
CURRENT RATING
2.3kW
9.6A
2.3kW
9.6A
2.3kW
9.6A
3.0kW
12.5A
3.0kW
12.5A
3.1kW
12.9A
3.1kW
12.9A
3.1kW
12.9A
5.3kW
22.4A
6.2kW
25.8A
8.7kW
36.3A
4.9kW
20.4A
5.3kW
22.1A
3.1kW
12.9A
WIRE
SECTION
(MM²)
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4.0
6.0
6.0
4.0
4.0
2.5

Advertisement