3/8" x 24" hydraulic hose, labeled #1, to the driver's side angle cylinder
adapter. Attach the 3/8" x 24" hydraulic hose, identified by a #2, to the
passenger's side angle cylinder adapter. Be careful not to over-tighten
the hose connections. Complete the hose installation by running each
hose through the access holes in the A-frame to their respective
manifold ports.
4. The PRESSURE & TANK HYDRAULIC HOSES attach to the ports on
the side of the manifold labeled "P" and "T". Verify that the 3/4" x 78"
hydraulic hose with the 1-1/16"-12 female swivel is attached to the
1-1/16"-12 x 1-1/16"-12 MALE O.R.B. CONNECTOR ADAPTER
located in the pressure port ("P"). The 3/4" x 78" hydraulic hose, with
the male O.R.B. 90˚ swivel, connects to the tank port ("T"). Once you
have completed the installation of the hydraulic hoses, begin to install
the wire harness.
Electrical Assembly - Control Wire Harness
1. Begin the installation by connecting the MALE ELECTRIC CONNEC-
TOR found on the COIL WIRE HARNESS (on manifold) to the FEMALE
ELECTRIC CONNECTOR on the WIRE HARNESS EXTENSION
(PLOW). Once both connectors are locked together, feed the opposite
end of the wire harness extension through the top access hole (same
as 3/4" tank hydraulic hose) in the A-frame located on the driver's side.
2. Locate the GROUND END RING TERMINAL on the coil wire harness
and wire harness extension. Using a 3/8"-16 x 1-1/2" hex cap screw
and 3/8" tooth lock washer, ground both wires to the A-frame. Secure
the wires using a 3/8" top lock nut. Review the diagram below for the
proper ground location.
Hydraulic manifold
(red anodized)
mount holes
3. Next, connect the MOLDED RUBBER CONNECTOR from the wire
harness extension (plow) to the connector on the WIRE HARNESS
EXTENSION (VEHICLE). Lock together the remaining male electric
connector on the PISTOL GRIP CONTROL HARNESS to the female
electric connector on the wire harness extension (vehicle). Complete
the electrical assembly by attaching the BLACK, GROUND wire from
the wire harness extension to the cab of the skid steer. The PINK/
BLACK POWER wire connects to a switched (on and off with ignition)
Hole location for
3/8"-16 x 1-1/2"
ground bolt
When handling the hydraulic manifold DO NOT
hold the manifold by the wire lead coils. The sole-
noid cartridges can bend, causing them to stick
when activated. Always carry the manifold by the
sides of the aluminum block.
Manifold Mount Holes
There are two sets of holes in the bottom plate on
the A-frame. One set contains two holes and is
used to mount the RED anodized manifold (see
diagram). The other set contains four holes and
can accept the CLEAR anodized manifold. When
mounting the red manifold, the hole in the upper
right serves as the location for the ground stud.
Use a 3/8"-16 x 1-1/2" bolt, tooth lock washer and
3/8"-16 top lock nut to secure the electrical
grounds to the A-frame.
Elec. Assem.- Control Wire Harn.
07

Advertisement

Table of Contents
loading