Summary of Contents for Daikin CTXJ25TVMAW

  • Page 1 DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Enjoy year-round comfort. Enjoy year-round comfort. Enjoy year-round comfort. Enjoy year-round comfort. Enjoy year-round comfort. MODELS CTXJ25TVMAW CTXJ35TVMAW CTXJ50TVMAW CTXJ60TVMAW CTXJ25TVMAK CTXJ35TVMAK CTXJ50TVMAK CTXJ60TVMAK...
  • Page 2: Table Of Contents

    4-7-1 Precautions when using the wireless adapter....14 and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. 4-7-2 To install the Daikin Mobile Controller application ..14 4-7-3 To set the wireless connection ........14 WARNING ....
  • Page 3 WARNING Never attempt. • Beware of fire in case of refrigerant leakage. If the Be sure to follow the instructions. air conditioner is not operating correctly, i.e. not generating cool or warm air, refrigerant leakage could Be sure to establish an earth connection. be the cause.
  • Page 4: About The System

    2. About the system CAUTION • Avoid impacts to the indoor and outdoor units, or CAUTION otherwise product damage may result. • Do not place flammable items, such as spray cans, The indoor unit contains radio equipment. Minimum separation distance within 1m of the air outlet.
  • Page 5: About The Remote Controller

    ON/OFF button h Select button i Clock button and open panel (push 2 seconds) If the remote controller is missing, you can use the ON/OFF j Buttons for ON/OFF timer operation button on the indoor unit to start/stop operation. When operation k Buttons for Weekly timer operation is started using this button, the following settings are used: l Streamer...
  • Page 6: To Operate The Remote Controller

    1. Choose a place where the signals reach the unit. 2. Attach the holder with screws to the wall or a similar location. Comfort operation is active 3. Hang the remote controller on the remote controller holder. Intelligent eye is active 3-2 To insert the batteries Automatic vertical swing is active Automatic horizontal swing is active...
  • Page 7: To Set The Clock

    3-3-1 To set the clock 4. To confirm the selected setting, press Result: The brightness setting is changed. Note: If the time is NOT set , and blink. Note: The display automatically returns to the default screen 1. Press after 60 seconds. To return to the default screen sooner, press Result: blink twice.
  • Page 8: Operation

    4. Operation Feature Tasks To automatically turn ON or OFF the ON timer + 4-1 Operation range system. timer Use the system in the following temperature and humidity To automatically turn ON or OFF the Weekly timer ranges for safe and effective operation. system on a weekly basis.
  • Page 9: Airflow Rate

    1. Press one or more times to select the operation mode. CAUTION Result: The mode will be set as follows: • ALWAYS use a remote controller to adjust the position of the flaps and louvres. When the flaps and louvres are swinging and you move them forcibly by hand, the mechanism will break.
  • Page 10: Comfort Airflow And Intelligent Eye Operation

    4-3-4 Comfort airflow and Intelligent eye operation To turn ON/OFF Vertical airflow function You can use Comfort and Intelligent eye operation separately, 1. Press for at least 2 seconds. or combine them. Result: The menu appears on the display. Comfort airflow operation 2.
  • Page 11: Powerful Operation

    To start/stop Comfort and Intelligent eye operation 4-3-6 Econo and Outdoor unit quiet operation Econo operation 1. Press one or more times. Result: The setting will change as follows: This is a function which enables efficient operation by limiting the maximum power consumption value. This function is useful for cases in which attention should be paid to ensure a circuit breaker will not trip when the product runs alongside other appliances.
  • Page 12: Flash Streamer Air Cleaning Operation

    • OUTDOOR UNIT QUIET operation will not reduce the 4-5-1 To start/stop OFF timer operation frequency nor fan speed if they already are operating at 1. Press to start. reduced levels. Result: is displayed on the LCD, the timer lamp •...
  • Page 13: To Combine Off Timer And On Timer

    4. To stop operation, press INFORMATION Result: disappear from the LCD and • Weekly timer and ON/OFF timer operation CANNOT be the timer lamp goes off. and the day of the week are used at the same time. The ON/OFF timer operation takes displayed on the LCD.
  • Page 14: To Copy Reservations

    4-6-3 To confirm reservations 8. Press to select the desired temperature. You can confirm if all reservations are set to your needs. Note: The set temperature for the weekly timer is displayed only when setting the weekly timer mode. 1. Press Result: The day of the week and the reservation number of the current day are displayed.
  • Page 15: Wireless Lan Connection

    • Microwave oven. It may affect wireless LAN communications. 1. Hold for at least 5 seconds in the default screen. 4-7-2 To install the Daikin Mobile Controller application Result: The confirmation display (menu ) appears. 1. Open: 2. Press repeatedly until the WPS setting display •...
  • Page 16 To reset the connection setting to the factory default 3. Press to confirm the selection. Result: is blinking. Reset the connection setting to the factory default in case you want to: 4. Press the WPS button on your communication device (e.g.router) within approximately 1 minute.
  • Page 17: Energy Saving And Optimum Operation

    5. Energy saving and optimum operation • Adjust the airflow direction to avoid cool air from gathering on the floor or warm air against the ceiling. (Up during cooling or dry operation to the ceiling and down during heating operation.) INFORMATION •...
  • Page 18: Night Quiet Mode (Available Only For Cool Operation)

    6-1-2 NIGHT QUIET mode (Available only for COOL Status of room B, C and D when Operation mode in operation) the unit in room A is in COOL room B, C and D operation NIGHT QUIET mode requires initial programming during installation.
  • Page 19: To Clean The Indoor Unit And Remote Controller

    7-3 To clean the front panel NOTICE Maintenance MUST be done by an authorized installer or service agent. We recommend performing maintenance at least once a year. However, applicable legislation might require shorter maintenance intervals. 1. Clean the front panel with a soft cloth. If it is difficult to remove stains, use water or a neutral detergent.
  • Page 20: To Clean The Air Filters

    7-6 To clean the air fi lters 7-7 To clean the titanium apatite deodorising fi lter 1. Hold the tab at the centre of each air fi lter and pull up a little. INFORMATION 2. Pull out the air fi lters. Clean the filter with water every 6 months.
  • Page 21: To Remove The Front Panel

    7-9 To remove the front panel 1. Press and select operation. • When a multi outdoor unit is connected, make sure the HEAT operation is not being used in other rooms before you INFORMATION use the FAN operation. Refer to page 16. Remove the front panel only in case it MUST be replaced.
  • Page 22 Malfunction Measure Malfunction Measure • Check if there is no power failure. • Check the airflow rate setting. Refer to If the system does The system NOT operate at all. Wait until power is restored. If a “4-3-2 Airflow rate” on page 8. operates,but power failure occurs during operation, cooling or heating is...
  • Page 23: Symptoms That Are Not System Malfunctions

    8-1 Symptoms that are NOT system malfunctions Malfunction Measure The following symptoms are NOT system malfunctions: The unit does NOT • Check the batteries of the remote receive signals controller. Refer to “3-2 To insert the 8-1-1 Symptom: A sound like water flowing is heard batteries”...
  • Page 24: Symptom: The Outdoor Fan Rotates While The Air Conditioner Is Not In Operation

    8-1-11 Symptom: The outdoor fan rotates while the air Outdoor unit conditioner is not in operation Error code Description • After operation has stopped. The outdoor fan continues to 4-way valve abnormality rotate for another 30 seconds for system protection. Outdoor unit PCB abnormality •...
  • Page 25: Disposal

    Problem Measure • Try switching between access The WLAN adapter is NOT visible in the available Wi-Fi point and WPS setting to networks list on the smart device change the wireless channel. (Access point option). The wireless channel MUST be between 1~13.