Acq Manual (Manual Acquisition) Mode; Using Manual Acquisition And Auto Acquisition Together - JRC JMR-5410-6X Simplified Instruction Manual

Marine radar equipment
Hide thumbs Also See for JMR-5410-6X:
Table of Contents

Advertisement

3.1.2 ACQ MANUAL (manual acquisition) mode

Memo
The manual acquisition mode does not function in the following states.
The number of tracked targets has reached the
maximum count.
The radar antenna is in the standby state.
A PROC (Interrupt) warning is being generated.
A Gyro (I/F)/Gyro (Data)/Heading (Data) warning is
being generated.
The tracked target is located 32 NM away from own
ship.
The tracked target is located less than 0.1 NM from
own ship.
To acquire the tracked target in the manual acquisition mode
1
Set the cursor mode to the AUTO mode.
2
Place the cursor on the target to be acquired and then click on.
The target is acquired and the initial acquisition symbol is displayed.
The vector is displayed within 1 minute.
3.1.3 Using manual acquisition and auto acquisition
together
By using manual acquisition with AZ enabled, auto acquisition and manual acquisition can be used
together. They may be used if a target to which particular attention should be given is manually
acquired and other targets are automatically acquired.
Section 3 Operation of Target Tracking
State
Target manually acquired.
The initial acquisition symbol is displayed.
Target that has passed for 1 min.
The acquisition symbol and vector are displayed.
Action to Take
Erase unnecessary targets.
Start the radar transmission.
Clear the warning.
The manual acquisition mode cannot be
used.
3-2

Advertisement

Table of Contents
loading

Table of Contents