M 11. Cleaning Heating Surfaces; System Start-Up - Viessmann Vitogas 100 Service Instructions Manual

Gas fired boiler for natural gas and lpg
Table of Contents

Advertisement

Further details regarding the individual steps
Clean the heating surfaces, if required

System start-up

¨ Safety instructions
Check the soundness of all sealing faces of gas pipes and fittings at operating
pressure with a foaming test agent (leak test spray).
Initial start-up, inspection and maintenance
(with the burner removed)
1. Release the self-tapping screws
and remove top panel A.
A
2. Release the tensioning springs,
thermal insulation mat B and
mineral fibre mat C.
B
3. Unscrew the lid from flue gas
collector D.
C
D
4. Clean the boiler body heating
surfaces (with burner removed)
using the cleaning brush supplied.
¨ Never use cleaning agents
containing potassium.
5. Remove residues from the bottom
plate.
6. H Fit the lid to the flue gas
collector.
H Position the mineral fibre mat
and the thermal insulation mat
and secure with the tensioning
springs to the boiler body
thermal insulation mat.
H Fit the top panel.
H Install the burner in reverse
order. Use new gaskets.
(cont.)