Colored Flame Led Light Assembly Replacement; Log Set Assembly Replacement - Dimplex DFR2651L Service Manual

Table of Contents

Advertisement

8. Properly orient and install the new LED lights and con-
nect all of the wiring.
9. Reassemble in the reverse order as above.
COLORED FLAME LED LIGHT
ASSEMBLY REPLACEMENT
Tools Required: Phillips Head Screwdriver
CAUTION: If unit was operating prior to servicing allow
at least 10 minutes for lights, heating elements and top
panel to cool off to avoid accidental burning of skin.
WARNING: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
1. Unplug the unit from power outlet.
2. Remove the firebox from the back of the mantel by
removing the retaining screws which secure the firebox
brackets to the mantel.
3. Remove the four screws along the back of the unit,
the two that hold the glass retaining bracket on both
sides and the two on either side along the bottom edge.
(Figure 5)
4. Lay the Compact Fireplace on its back.
5. Gently open the bottom panel, laying it on the work sur-
face so that all of the components can easily be seen.
(Figure 6)
6. Locate the strip of LED lights along the back and the
strip of LED lights on the brack at the front.
7. Release the LED light strips from the support panels
by using needle nose pliers to depress the tab on the
mounting standoffs and gently lift the board off.
8. Disconnect the wiring connections noting their original
location.
9. Properly orient and install the new LED lights and con-
nect all of the wiring.
10. Reassemble in the reverse order as above.
Figure 7
Back
Ledge
Rear
Tab
10
Log
Ember
Bed
Front
Side Section
Edge

LOG SET ASSEMBLY REPLACEMENT

Tools Required: Phillips Head Screwdriver
CAUTION: If unit was operating prior to servicing allow
at least 10 minutes for lights, heating elements and top
panel to cool off to avoid accidental burning of skin.
WARNING: Disconnect power before attempting any
maintenance to reduce the risk of electric shock or damage
to persons.
1. Unplug the unit from power outlet.
2. Remove the firebox from the back of the mantel by
removing the retaining screws which secure the firebox
brackets to the mantel.
3. On the right side, remove the three screws to remove
the trim off of the unit.
4. Remove the front glass and set aside in a safe place.
5. Pull the front edge of the plastic Ember Bed or plastic
grate up and forward until the rear tab releases from
the ledge located at the bottom of the Partially Reflect-
ive Panel. (Figure 7)
! IMPORTANT: Only handle the Log Set by the Ember
Bed.
! NOTE: Log Set fits tightly into firebox, some force may
be necessary to remove.
6. Disconnect the wiring connections noting their original
location.
7. Remove the two screws on each side that secure the
log set support brackets to the firebox remove the par-
tially reflective panel by sliding it out of the side chan-
nels towards the bottom. (Figure 7)
8. Reassemble in the reverse order as above.
Figure 8
Partially
Reflective
Panel
Display/
Control
Board
Support
Bracket
www.dimplex.com