Sharp R-1500AT Service Manual page 25

Commercial microwave oven
Table of Contents

Advertisement

4. Exhaust thermistor check (SF-6)
You can check if the exhaust thermistor works correctly or not by using this function.
For example: In case the exhaust thermistor works correctly (275ml water load is necessary.), the display will show "OH" as follows.
Operation
plug in
(within 20 sec.)
POWER LEVEL
SET MEMORY
(within 20 sec.)
START
STOP/CLEAR
START
(after 5 min.)
STOP/CLEAR
STOP/CLEAR
For example: In case the exhaust thermistor works incorrectly (275ml water load is necessary), the display will show "no" as follows. In
that case, the exhaust thermistor should be checked or replaced.
Operation
plug in
(within 20 sec.)
POWER LEVEL
SET MEMORY
(within 20 sec.)
START
STOP/CLEAR
START
(after 5 min.)
STOP/CLEAR
STOP/CLEAR
Display
0
0
0
0
SF-
SF-6
6
5.00
(count down)
OH
SF-1
0
Display
0
0
0
0
SF-
SF-6
6
5.00
(count down)
no
SF-1
0
Indicator
Sound
ON
or
or
Indicator
Sound
ON
or
7 – 4
R1500AT

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-2100at

Table of Contents