JUNCTION BOX DETAIL
FIGURE 25

1.5 FAN

These heaters have a factory installed Fan, Electrical
Junction Boxes, variable speed Rheostat Control Switch
and Temperature Sensor Switch for the fan. These com-
ponents are located behind the lower grille.
Use of the fan requires that the Junction Box (factory
installed) be connected to 240 VAC service before per-
manently enclosing the heater. The factory installed
power cord is attached on the lower front right exterior
side of the heater. Figure 25 shows the fan, switches,
and fan wiring diagram. See Figure 26 for wire connec-
tion detail.
JUNCTION BOX
TEMPERATURE
SENSOR SWITCH
FAN
BLK
TEMP. SENSOR
JUNCTION BOX
YELLOW/GRN
GRD
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
FAN SPEED
105
CONTROL
SPEED CONTROL
BLK
BLK
SWITCH
BLK
BLK
BLUE
BRN
YELLOW/GRN
WARNING: DO NOT CONNECT 220 V AC TO THE
GAS CONTROL VALVE OR CONTROL WIRING SYS-
TEM OF THIS MODEL.
NEUTRAL (BLUE)
HOT (BROWN)
BLACK
FIGURE 26
17
C RATED WIRE.
FAN WIRING DIAGRAM
BLK
BLUE
BLUE
BRN
BROWN
YW/GR
YELLOW/GREEN
FAN
BLUE
BLACK
BROWN